SMCCO10-Z CO Alarm User Guide
Copyright
©
2013 SMC Networks
Page 8
All Rights Reserved
I/M SMCC010-Z rev. 1.0
1/23/2013
9/3/10
A.
Wait at least 10 minutes after
installing the SMCCO10-Z.
B.
Be sure the green Power LED is
flashing for normal operation.
C.
Set the Touchscreen to sensor test
mode.
D.
Press and hold the
Test/Hush
button
until the SMCCO10-Z beeps 3 times
(approximately 10 seconds), then
release the button. The SMCCO10-Z
enters functional gas test mode.
The Power LED blinks once per
second in this test mode.
E.
Apply a UL-approved CO test agent
to the slit as shown in Figure 7
below. When CO is detected, the
SMCCO10-Z activates a CO alarm.
The SMCCO10-Z sends RF test
packets to the Touchscreen when
the CO alarm activates.
Figure 6. CO Testing Slit
F.
The Touchscreen beeps and shows
the number of RF packets received.
G.
At the Touchscreen, exit sensor test
mode.
H.
Exit functional gas test mode:
I.
Press and release the
Test/Hush
button. Alternatively, a 2-minute
timeout returns the SMCCO10-Z to
normal operating mode
automatically.
7
Defaulting the SMCCO10-Z
Note:
This step should only be
performed by a qualified service
technician.
A.
Slide the alarm body off of the
mounting plate.
B.
Remove all three batteries.
C.
Remove the access door on
SMCCO10-Z top cover.
D.
Press the enrollment switch in the
RF circuit inside the SMCCO10-Z and
hold until you replace the batteries.