SS0755
08 C4
S kit
EX510 serial wiring
SA
Voltage: 24 VDC
S07 1 5
5 MO
Base mounted plug lead
0
1
8
9
6
7
14
15
S
Refer to pages 1696 to 1724 for the details of EX510 gateway system
serial transmission system.
Note) Not compatible with dual 3 port valves.
S0700
Kit (Serial Transmission System)
EX510 Gateway System Serial Transmission System
SI unit COM.
+COM.
–COM.
Nil
N
Stations
Symbol
02
16
Stations
2 stations
16 stations
···
···
Standard
station
1 to 8 stations
Max. number of
stations for special
wiring specification
16 stations
Max. number of
solenoids
16
Note) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter “-K” to the order code options.
Single type
1
Double, Dual 3 port type
2
Type of actuation
Number of solenoids
How to Order Manifold
Symbol
Nil
K
Note 2)
R
Note 3)
Option
None
Special wiring specification
(Except double wiring)
External pilot
Option
Note 1) When two or more options are specified,
indicate them alphabetically. Example) -KR
Note 2) Indicate the wiring specification for mixed
single and double wirings.
Note 3) For details, refer to page 664.
∗
For manifold optional parts, refer to pages 664
to 666.
P, R Port thread type
Nil
Symbol
F
N
T
Manifold pitch
8.5
Rc (PT)
G (PF)
NPT
NPTF
Cylinder port size
Symbol
M5
C2
C3
C4
CM
N1
N3
NM
Port size
M5 thread
With one-touch fitting for ø2
With one-touch fitting for ø3.2
With one-touch fitting for ø4
Mixed size/with port plug
Note)
With one-touch fitting for ø1/8"
With one-touch fitting for ø5/32"
Mixed size/with port plug
Note)
Metric
Inch
Note) Specify “Mixed size/with port plug” in the manifold
specification sheet.
How to Order Valves
Type of actuation
Note) For JIS symbol, refer to page 616.
Symbol
1
2
A
B
C
Specification
2 position single
2 position double
4 position dual 3 port type
(N.C. + N.O.)
4 position dual 3 port type
(N.O. + N.O.)
[Pressure center]
4 position dual 3 port type
(N.C. + N.C.)
[Exhaust center]
Specification
Standard
External pilot
Note)
Symbol
Nil
R
Function
Electrical entry
M plug connector, without lead wire
(Light/surge voltage suppressor)
1 set – Manifold base part no.
3 sets – Valve part no. (Stations 1 to 3)
3 sets – Valve part no. (Stations 4 to 6)
2 sets – Valve part no. (Stations 7 to 8)
<Example>
Lead wire kit
SS0755-SA08C4 ·····
∗
S0715-5G ··············
∗
S0725-5G ··············
∗
S07A5-5G ··············
How to Order Manifold Assembly
Specify the part numbers for valves and op-
tions together beneath the manifold base
part number.
Prefix the asterisk to
the part nos. of the
solenoid valve, etc.
Write sequentially from the
1st station on the D side.
When part nos. written
collectively are complicated,
specified by using the
manifold specification sheet.
The connector assembly lead
wire length used for EX510
manifold varies depending on
the number of stations.
Therefore, solenoid
valves (including a
blanking plate) and
connector
assembly are
assembled when
shipped as a
standard
specification.
Please specify the
mounting solenoid
valve when
ordering.
D side
U side
3 2
1
Stations
662
P0609-P0680-E080904.qxd 08.9.4 11:34 AM Page 662