SS0750
FD1
08 C4
B
S07 1 0
5
Base mounted plug-in
Note) Not compatible with dual 3 port valves.
How to Order Manifold
Stations
Symbol
02
24
Stations
Cylinder port size
Symbol
C2
C3
C4
CM
N1
N3
NM
Port size
With one-touch fitting for ø2
With one-touch fitting for ø3.2
With one-touch fitting for ø4
Mixed size/with port plug
Note)
With one-touch fitting for ø1/8"
With one-touch fitting for ø5/32"
Mixed size/with port plug
Note)
Metric
Inch
Option
Note) The maximum number of stations
will be different depending on the
wiring specification.
Note) Specify “Mixed size/with port plug” in the manifold
specification sheet.
Kit name / Cable length
F kit
Kit
name
Specification
Symbol
D-sub connector (25P), without cable
D-sub connector (25P), with 1.5 m cable
D-sub connector (25P), with 3.0 m cable
D-sub connector (25P), with 5.0 m cable
Standard station
1 to 12 stations
Max. number of
stations for special
wiring specification
24 stations
Max. number of
solenoids
24
FD0
FD1
FD2
FD3
Note) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter “-K” to the order code options.
Single type
1
Double, Dual 3 port type
2
Type of actuation
Number of solenoids
B
Note 2)
D
D0
D
Note 3)
K
Note 4)
N
R
Note 5)
S
Option
None
With back pressure check valve
(all stations)
With DIN rail (Rail length: Standard)
Without DIN rail (with bracket)
With DIN rail Designated length
(
: station)
Special wiring specification (Except
double wiring)
With name plate
External pilot
Built-in silencer
Note 1) When two or more options are specified,
indicate them alphabetically. Example) -BRS
Note 2) When installing a back pressure check valve
on the required station, enter the part number
and specify the station position in the manifold
specification sheet.
Note 3) The available number of stations is larger than
the number of manifold stations.
Note 4) Indicate the wiring specification for mixed
single and double wirings.
Note 5) For details, refer to page 648.
∗
For manifold optional parts, refer to pages 648 to
652.
∗
For manifold exploded view, refer to page 654.
2 stations
24 stations
Note)
Symbol
Nil
···
···
How to Order Valves
Type of actuation
Note) For JIS symbol, refer to page 616.
Symbol
1
2
A
B
C
Specification
2 position single
2 position double
4 position dual 3 port type (N.C. + N.O.)
4 position dual 3 port type (N.O. + N.O.)
[Pressure center]
4 position dual 3 port type (N.C. + N.C.)
[Exhaust center]
Symbol
5
6
Specification
24 VDC
12 VDC
Voltage
Specification
Standard
External pilot
Note)
Symbol
Nil
R
Function
How to Order Manifold Assembly
<Example>
Serial transmission kit
SS0750-08C4FD1 ······
∗
S0710-5 ···················
∗
S0720-5 ···················
∗
S07A0-5 ···················
∗
SS0700-10A-1 ·········
Specify the part numbers for valves and
options together beneath the manifold base
part number.
Prefix the asterisk to
the part nos. of the
solenoid valve, etc.
1 set – Manifold base part no.
3 sets – Valve part no. (Stations 1 to 3)
2 sets – Valve part no. (Stations 4 to 5)
2 sets – Valve part no. (Stations 6 to 7)
1 set – Blanking plate part no. (Station 8)
Write sequentially from the
1st station on the D side.
When part nos. written
collectively are complicated,
specified by using the
manifold specification
sheet.
1 2 3 ······ S
tations
D side
U side
625
Plug-in
S0700
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P0609-P0680-E080904.qxd 08.9.4 11:34 AM Page 625