How to Add Manifold Stations (Plug-in Type / Lead Wire Connection Type)
What to order
Manifold block assembly (Refer to page 655.)
Steps for adding stations
Loosen hexagon bolts from the end plate at the U side and remove the
end plate.
Connect the tie rod for increasing the station number, open the junction
cover, mount the manifold block assembly and U-side end plate and
tighten them by hexagon bolts.
(Tightening torque: 0.85 to 0.95 N
폷
m)
Connect lead wire assemblies included with manifold blocks as follows.
Take out the socket housing and connect the black and white lead wires.
The connection layout is common to all kits.
2A
3A
4A
13A
1B
2B
3B
4B
5B
6B
7B
8B
9B
10B
11B
12B
13B
5A
6A
7A
8A
9A
12A
11A
10A
COM.
Red
Red
COM.
Black
1 station
SOL.A
SOL.A
2 stations
Black
SOL.B
3 stations
White
SOL.B
4 stations
White
Black
3 stations
SOL.A
Black
4 stations
SOL.A
Black
5 stations
SOL.A
SOL.B
5 stations
White
Black
6 stations
SOL.A
1A
Tie-rod for station additions
Convex part
Socket housing
Junction cover
Round type terminal
U side end plate
Hexagon socket head screw
Tightening torque: 0.85 to 0.95 N
폷
m
Convex part
Red
Terminal no.
White
Black
Tightening torque: 0.25 to 0.35 N
폷
m
656
Series
S0700
P0609-P0680-E080904.qxd 08.9.4 11:34 AM Page 656