JIS symbol
Note 1) The dual 3 port valve is
not available.
Note 2) When the internal pilot
type and external pilot
type of valves are mixed
up on the manifold, or-
der the manifold suit-
able for the specifica-
tions of the external pi-
lot valve.
Note 3) Valves with the external
pilot have a pilot EXH
with individual exhaust
specifications and EXH
can be pressurized.
However, the pressure
supplied from EXH
should be 0.4 MPa or
lower.
Exhaust port
Spacer for Individual SUP/EXH
If this spacer is installed instead of a valve, it
is possible to add SUP and EXH ports. In
this condition, the A port should be an SUP
port and the B port an EXH port.
∗
Specify the spacer mounting position and
SUP/EXH passage shut off positions on the
manifold specification sheet.
∗
The spacer comes with a SUP block plate
and an EXH block plate.
∗
Electrical wiring is also connected to the
spacer mounting position.
A
4
B
2
A
4
B
2
A
4
B
2
8.5
57
A
4
B
2
A
4
B
2
A
4
B
2
8.5
57
SS0700-PR-1
EXH
port
SUP
port
D side
Valve
Block plate (Ordering not required)
BA
BA
PR
3(R)
1(P)
Valve
Spacer for
Individual
SUP
EXH
Series
S0700
Plug-in
Manifold Optional Parts
Blanking plate
SS0700-10A-1
It is used by attaching on the manifold block
for being prepared for removing a valve for
maintenance reasons or planning to mount a
spare valve, etc.
Mass: 25 g
External pilot [-R]
This can be used when the air pressure is 0.1 to
0.2 MPa lower than the minimum operating pres-
sure of the solenoid valves or used for vacuum
specifications.
Add R to the part numbers of manifolds and
valves to indicate the external pilot specification.
An M5 port will be installed on the top side of the
manifold’s SUP/EXH block.
How to Order Valves (Example)
S0710 R -5
How to Order Manifold (Example)
∗
Indicate R for an option.
SS0750-08C4FD1-R
External pilot
External pilot
External pilot port
(M5 x 0.8)
Built-in silencer, Direct exhaust [-S]
Note) A large quantity of drainage generated in the
air source results in exhaust of air together
with drainage.
∗
When ordering assemblies incorporated with a
manifold, add suffix “-S” to the manifold no.
∗
For precautions on handling and how to replace
elements, refer to “Specific Product Precautions.”
This is a type with an exhaust port atop the manifold end
plate. The built-in silencer exhibits an excellent noise
suppression effect. (Silencing effect: 30 dB)
648