Warning
Caution
Replacement of Cylinder Port Fittings
Internal Wiring Specifications
Note) Coil surge voltage generated when OFF is about –60V. Please contact
SMC separately for further suppression of the coil surge voltage.
SOL.A
Varistor
(+)
(–)
SOL.A
Varistor
SOL.B
Varistor
COM (+)
(–)
(–)
The cylinder port fittings are a cassette for easy re-
placement. The fittings are blocked by a clip inserted
from the top of the valve.
Remove the clip with a screwdriver to remove fittings.
For replacement, insert the fitting assembly until it
strikes against the inside wall and then re-insert the
clip to the specified position.
Applicable tubing O.D.
Applicable tubing ø2
Applicable tubing ø3.2
Applicable tubing ø4
Applicable tubing ø1/8"
Applicable tubing ø5/32"
VVQ0000-50A-C2
VVQ0000-50A-C3
VVQ0000-50A-C4
VVQ0000-50A-N1
VVQ0000-50A-N3
One-touch fitting part no.
∗
Part number is for one fitting assembly. Please order it in 10-piece units.
8.5 mm pitch
7.5 mm pitch
Applicable tubing ø2
Applicable tubing ø3.2
Applicable tubing ø4
Applicable tubing ø1/8"
Applicable tubing ø5/32"
Barb fitting ø2
Barb fitting ø3.2
Barb fitting ø4
VVQ0000-50A-C2
VVQ0000-50A-C3
VVQ0000-50A-C4
VVQ0000-50A-N1
VVQ0000-50A-N3
SS070-50A-20
SS070-50A-32
SS070-50A-40
Applicable tubing O.D.
Barb fitting part no.
∗
Part number is for one fitting assembly. Please order it in 10-piece units.
Clip
Fitting
assembly
Clip
Fitting
assembly
Plug lead
Plug-in
Light/surge voltage suppressor
No polarity by adopting non-polar light.
Indicator light
B side
Indicator light
A side
Plug-in
Indicator light
B side
Indicator light
A side
Plug lead
Plug-in Double, Dual 3 Port
Plug-in Single/All plug lead types
Series
S0700
Specific Product Precautions 3
Be sure to read before handling.
Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port
Solenoid Valve Precautions.
673
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P0609-P0680-E080904.qxd 08.9.4 11:34 AM Page 673