48
-
No.JXC
※
-OMU0030-A
10. Initial setting value of electric actuator (LEM series)
The default setting values are shown below.
Return to origin, jog operation, inching operation are as shown in the table below.
Common to LEM series
Return to origin
Direction
Motor side
Speed [mm/s]
60
Acceleration [mm/s
2
]
500
Jog operation
Speed [mm/s]
48
Acceleration [mm/s
2
]
1000
Inching operation
Distance [mm]
0.12
Refer to the table below for the speed and the acceleration of the LEM series.
LEMB / LEMC
LEMH / LEMHT
Speed
[mm/s]
Acceleration
[mm/s
2
]
Speed
[mm/s]
Acceleration
[mm/s
2
]
0
48
250
48
250
1
75
500
75
500
2
100
1000
100
1000
3
150
1500
150
1500
4
200
2000
200
2000
5
250
2500
300
2500
6
300
3000
400
3000
7
350
4000
500
4000
8
400
5000
600
5000
9
450
6000
800
6000
10
500
7500
1000
7500
11
600
10000
1200
10000
12
700
12500
1400
12500
13
800
15000
1600
15000
14
900
17500
1800
17500
15
1000
20000
2000
20000