46
-
No.JXC
※
-OMU0030-A
(2) Positioning operation
:
Driving to the stroke end and Driving to the intermediate position
-
Procedure
- Driving to the stroke end
- -Timing chart-
Driving to the stroke end
1) Turn on IN0 (To end side) or IN1 (To motor
side) input signal.
↓
2) OUT turns OFF and BUSY output signal turns
on.(Starts to drive to stroke end)
↓
3) From a few mm of stroke end,
OUT0 output
signal turns on when turning on IN0 input
signal.
OUT1 output signal turns on when
turning on IN1 input signal.
↓
4) BUSY output turns off.
(The electric actuator stops.)
After OUT0 or OUT1 output turns on, the
electric actuator drives to the stroke end and
stops. Then, BUSY output turns off.
↓
5) Driving to the stroke end is completed.
-
Procedure
- Driving to the intermediate position -
-Timigng chart-
Driving to the intermediate
position -
1) Turn on IN0 to IN3 input signals.
(Inputs the position number with the
binary by the combination of IN0-IN3.)
When one command is made by inputting
several I/O simultaneously, the time
difference between signals has to be 3 ms
or less.
↓
2) BUSY is turned on.
(The positioning operation starts.)
↓
3) BUSY output turns off.
(The electric actuator stops)
OUT0 to OUT3 outputs corresponding to the
commanded IN0 to IN3 input signals turns on.
↓
4) Driving to the intermediate position is completed.
Power
IN0-3
OUT0 to 3
BUSY
External Lock
Output
Input
Electric actuator
Speed
Positioning operation
24V
0V
ON
OFF
ON
OFF
・
・
OFF
ON
0mm/s
When positioning is complete. the OUT
output which number is the same as the IN
Power
IN0 or 1
OUT0 or 1
BUSY
External Lock
Output
Input
Electric actuator
Driving to the stroke end
Speed
24V
0V
ON
OFF
ON
OFF
・
・
OFF
ON
0mm/s
A few mm before the stroke end, the
OUT output which number is the same