6.3 Details of parallel input / output signal and cable
(1) Parallel I/O cable(LEC-CK4-
□
)
Controller side
PLC side
Item
Specification
Connector
Manufacturer : J.S.T. Mfg.Co.,Ltd.
Product number : PADP-14V-1-S
Conductor size
AWG26
Length (L)
The suffix of the part number (1,3,5) specifies the length.
LEC-CK4-1: 1.5m LEC-CK4-3: 3m LEC-CK4-5: 5m
(2) Derails of input / Output signal
Terminal
No.
Insulation
color
Dot
Mark
Dot color Function Contents
1
Light
brown
■
Black
COM+
Connect the 24 V side of the power supply (24 VDC) for input /
output signal.
2
Light
brown
■
Red
COM-
Connect the 0 V side of the power supply (24 VDC) for input /
output signal.
3
Yellow
■
Black
OUT0
Operation completion output
(Output with the combination of OUT0 to OUT3)
*1)
・
When the return to origin is performed
:
OUT0 output is turned on only when the return to origin is
commanded by IN0.
OUT1 output is turned on only when thereturn to origin is
commanded by IN1.
・
Command the target position (end side or motor end):
OUT output equal to the IN input is turned on at the
position several mm away from the end.
・
Target position is intermediate position of the stroke:
After stopping at the target position, OUT output equal to
the IN input is turned on.
Example) Output the operation completion of position No. 3
OUT3 OUT2 OUT1 OUT0
OFF
OFF
ON
ON
After the external stopper of the
electric
actuator is adjusted,
when the operation to motor side or end side is commanded
without the stroke study, the
electric
actuator might not be
reached to the stroke ends. In that case, the OUT output
state is kept, and the alarm is not generated. Perform the
stroke study and register all of the intermediate positions
after adjusting the external stopper.
4
Yellow
■
Red
OUT1
5
Light
green
■
Black
OUT2
6
Light
green
■
Red
OUT3
7
Grey
■
Black
BUSY
BUSY signal (Turning ON during operating)