34
-
No.JXC
※
-OMU0030-A
4)
Move the electric actuator slider to the position to register
slowly using external force.
5) Keep pressing the set button (g) from the flashing
state of the 7-segment LED (f) until it remains on, for
registration of the position.
If you perform procedure
(4) Test run
before performing
return to origin, an alarm is generated (7-segment
LED(f) displays [A] and alarm LED (b) will turn on).
In this case, press the set button (g) to release the
alarm. Then perform return to origin
6) Press the Forward button (i) and Reverse button (j) simultaneously until the power supply LED
(a) changes from flashing to the on state. Returns to servo ON state.
Positioning by direct teaching is complete.
Caution
The slider of the electric actuators with a smaller lead may not be moved by the external force.
Perform (A) Position setting by Jog operation and Inching operation on the previous page.
(g)
(i)
(j)