- 51 –
No.JXC
※
-OMY0002
(
4
)
HOLD
-Procedures- - Timing chart HOLD -
1) HOLD is turned ON during the operation
(When HOLD is ON).
↓
2) BUSY is turned OFF
(The electric actuator stops).
↓
3) HOLD is turned OFF.
↓
4) BUSY is turned ON
(The electric actuator restarts).
(
5
)
Reset
-Procedures- [Driving reset] - Timing chart Driving reset -
1) RESET is turned ON during the operation
(BUSY output is ON).
↓
2) The OUT0 to OUT5 (OUT) are turned OFF.
↓
3) The "BUSY" output turns OFF.
(The electric actuator stops.)
-Procedures- [Alarm reset] -Timing chart Alarm reset -
1) An alarm is activated.
(*ALARM is turned OFF and the output OUT0
to OUT3 is turned ON.)
↓
2) RESET is turned ON.
↓
3) *ALARM is turned ON and the output OUT0 to
OUT3 is turned OFF (The alarm is deactivated).
Slow-down starting point
Electric actuator
RESET
OUT0~5
BUSY
INP
Output
Input
E
lectric actuator
ON
OFF
ON
OFF
ON
OFF
OFF
ON
Speed
0mm/s
If the electric actuator is within the "In position" range, INP will be
turned ON.
RESET
OUT0 to 5
*ALARM
The “*ALARM” is expressed as negative-logic circuit.
Output
Input
ON
OFF
ON
OFF
ON
OFF
Slow-down
starting point
Alarm out