Number of inputs, open-circuit detection, and connector
Enclosed parts
Round head screw with washer
(M4 x 20) 1 pc.
P-tight screw (4 x 14) 2 pcs.
DX P B
t
EX600 digital input unit
EX600
Input type
Mounting
ED 2
y
EX600 end plate
EX600
Power connector
ZMA3
u
Clamp bracket for EX600
EX600
Manifold Parts Nos.
Symbol Description
P
PNP
N
NPN
Symbol Number of inputs Open-circuit detection
Connector
B
8
No
M12 connector (5 pins) 4 pcs.
C
8
No
M8 connector (3 pins) 8 pcs.
C1
8
Yes
M8 connector (3 pins) 8 pcs.
D
16
No
M12 connector (5 pins) 8 pcs.
E
16
No
D-sub connector (25 pins)
F
16
No
Spring type terminal block (32 pins)
Number of outputs and connector
DY
B
P
t
EX600 digital output unit
EX600
Output type
Symbol Description
P
PNP
N
NPN
Symbol Number of outputs
Connector
B
8
M12 connector (5 pins) 4 pcs.
E
16
D-sub connector (25 pins)
F
16
Spring type terminal block (32 pins)
Number of inputs/outputs and connector
DM
E
P
t
EX600 digital input/output unit
EX600
Input/Output type
Symbol Description
P
PNP
N
NPN
Symbol Number of inputs Number of outputs
Connector
E
8
8
D-sub connector (25 pins)
F
8
8
Spring type terminal block (32 pins)
Number of input channels and connector
t
EX600 analogue input/output unit
EX600
AX A
Analogue input/output
Symbol
Description
AX
Analogue input
AY
Analogue output
Symbol Number of input channels
Connector
A
2 channels
M12 connector (5 pins) 2 pcs.
Analogue input/output
Number of input/output channels and connector
AM B
EX600
t
EX600 analogue input/output unit
Symbol Number of input channels Number of output channels
Connector
B
2 channels
2 channels
M12 connector (5 pins) 4 pcs.
Symbol Number of ports
Connector
B
4 ports
M12 connector
(5 pins) 4 pcs.
Symbol
Connector
2
M12 power supply connector, B-coded
3
7/8 inch power supply connector
4
M12 power supply connector IN/OUT,
A-coded, Pin arrangement 1
5
M12 power supply connector IN/OUT,
A-coded, Pin arrangement 2
Symbol
Description
—
Without DIN rail mounting bracket
3
With DIN rail mounting bracket
∗
The pin layout for the “4” and “5” pin
connectors is different.
EX600-ED4/5-
EX600-ED3-
EX600-ED2-
The applicable SI unit models are the PROFINET
compatible EX 6 0 0 -SPN 3 and EX 6 0 0 -SPN 4 . While
there is also an EtherNet/IP™ compatible made-to-
order specifi cation, the EX600-SEN3-X80, the manifold
will also need to be made to order in this case.
Caution
Number of ports and connector
L
1
A
t
EX600 IO-Link master unit
EX600
Port specifi cation
Symbol
Description
A
Port class A
B
Port class B
B
JSY1000/3000/5000
Series
110