Dimensions:
JSY1000
Series
L3: DIN Rail Overall Length
Valve stations
(n1)
I/O
unit
stations (n2)
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
0
185.5 185.5 198
198
210.5 210.5 223
223
235.5 235.5 248
248
260.5 260.5 273
273
285.5 298
298
310.5 310.5 323
323
1
198
210.5 210.5 223
223
235.5 235.5 248
260.5 260.5 273
273
285.5 285.5 298
298
310.5 310.5 323
323
335.5 335.5 348
2
223
235.5 235.5 248
248
260.5 260.5 273
273
285.5 285.5 298
298
310.5 310.5 323
323
335.5 335.5 348
348
360.5 360.5
3
248
248
260.5 260.5 273
273
285.5 285.5 298
298
310.5 310.5 323
323
335.5 348
348
360.5 360.5 373
373
385.5 385.5
4
260.5 273
273
285.5 285.5 298
310.5 310.5 323
323
335.5 335.5 348
348
360.5 360.5 373
373
385.5 385.5 398
398
410.5
5
285.5 298
298
310.5 310.5 323
323
335.5 335.5 348
348
360.5 360.5 373
373
385.5 385.5 398
398
410.5 410.5 423
435.5
6
310.5 310.5 323
323
335.5 335.5 348
348
360.5 360.5 373
373
385.5 398
398
410.5 410.5 423
423
435.5 435.5 448
448
7
323
335.5 335.5 348
360.5 360.5 373
373
385.5 385.5 398
398
410.5 410.5 423
423
435.5 435.5 448
448
460.5 460.5 473
8
348
360.5 360.5 373
373
385.5 385.5 398
398
410.5 410.5 423
423
435.5 435.5 448
448
460.5 460.5 473
485.5 485.5 498
JJ5SY1-10S
(
D
)
-
-
U
D
B
C2
C4
Stations
∗
These fi gures show the “JJ5SY1-10SQ1A-05D-C4.”
∗
Refer to page 97 for dimensions of external pilot (Made to Order) and
silencer.
∗
When CM is selected for mixed A, B port size and C6 (9 mm pitch) is
included, refer to page 100 for dimensions.
L1 = 6.5 x n1 + 139 + 21 x n2
L2 = 6.5 x n1 + 43.4
L4 = L3 − 10.5
L5 = (L3 − L1) / 2
L6 = 21 x n2 + 83.8
n1: Number of valve stations of the JSY1000
n2: Input block stations
Type
10
/
Side
Ported
(App
l
icable to
Ø
2 and
Ø
4 fi ttings)
EX250
ngs)
JSY1000/3000/5000
Series
(
L4
)
4 x M8
P = 6.5
66
9
.1
1.1
63
21
18
L1
(
L5
)
(12.2)
(14.8)
(8)
78.5
66.5
47.3
(3
9
.3)
5.3
2.2
9
.5
(35)
4.6
(5.5)
(
L3
)
L2
L6
(5.3)
5.5
1.5
23.
9
60
8.
9
13.2
2 x M12
23
10.2
(21)
5
9
.
9
27
(7.5)
13.6
10.3
M3
(
9
1.7)
(11.8)
0
2
3
1
A
B
4A
B
2
A
B
4A
B
2
A
B
4A
B
2
A
B
4A
B
2
S
D
D
4 A
B
2
4 A
B
2
4 A
B
2
4 A
B
2
E
3/5
P
1
PWR
BUS
3
2
1
0
3/5
1
P
E
4 A
B
2
Light/surge voltage suppressor
DIN rail holding screw
(For DIN rail mounting)
4 x M4 Mounting hole
(Recommended tightening torque: 1.4 N.m)
2 x M4 Mounting hole
(Recommended tightening
torque: 1.4 N.m)
(Fitting for the type with
P/E ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(DIN rail)
SI unit
Input block
Station 1
Pitch
3-pin socket
Station n
One-touch fi tting
[4(A), 2(B) port]
Applicable tubing O.D. C2: Ø 2 (SMC)
C4: Ø 4 (SMC)
Manual override
(Non-locking)
4(A) port side: Blue
2(B) port side: Yellow
One-touch fi tting
[1(P), 3/5(E) port]
Applicable tubing O.D.: Ø 8 (SMC)
Manifold block internal wiring specifi cations
—: Double wiring
S : Single wiring
D side
U side
(For DIN rail
mounting)
80