LOCK
FREE
1.3
46.2
(Station 1)
(Station n1)
(Station 1)
(Station n2)
P
1
E
3/5
D
D
S
2
B
4
A
2
B
4
A
2
B
4
A
2
B
4
A
2
B
4
A
P
1
E
3/5
PV
PD
PV
PD
V
V
V
V
1
1
Manifold block internal wiring specifications
Nil: Double wiring
S : Single wiring
17.1
23.
9
38.1
One-touch fitting
[1(P), 3/5(E) port]
Applicable tubing O.D.: Ø 10 (SMC)
17.3
18
15
15
3.5
P = 15
8.4
26.4
7
9
62
53
45.
9
38
(7.5)
(11.8)
(For DIN rail mounting)
66
10.
9
15.8
(Pitch)
P = 11.5
Applicable tubing O.D. C6: Ø 6 (SMC)
C8: Ø 8 (SMC)
One-touch fitting
[4(A), 2(B) port]
Applicable tubing O.D. 06: Ø 6 (SMC)
08: Ø 8 (SMC)
One-touch fitting
(Built-in suction filter)
[Vacuum (V) port]
One-touch fitting
[Common supply (PV) port]
Applicable tubing O.D.: Ø 8 (SMC)
∗
Excludes when the individual supply specification (symbol: -L) is selected
37.4
2B
4A
B A
2B
4A
B A
2B
4A
B A
2B
4A
B A
PS
PS
U side
D side
(10.5)
9
.1
12.8
88.8
70
(35)
(5.5)
(8)
L7
42
L1
1.5
1.5
(
L5
)
(DIN rail)
DIN rail holding screw
(For DIN rail mounting)
83
9
.
9
(5.3)
(14.8)
(14.
9
)
(
L4
)
(DIN rail mounting hole pitch: 12.5)
(
L3
)
L2
(For P/E ports on the
U side or both sides)
Manual override (Non-locking)
4(A) port side: Blue
2(B) port side: Yellow
6 x M4 Mounting hole
(Recommended tightening
torque: 1.4 N·m)
Manual override (Release valve)
Manual override
(Supply valve)
Light/surge voltage suppressor
JJ5SY3-10
-
∗
ZZK2
-M
S0-
A-A
U
D
B
1
2
Dimensions:
JSY3000
Series
For details on ejectors, refer to the ZK2
A series in the
Web Catalogue
.
∗
Refer to page 125 for dimensions of external
pilot and built-in silencer.
∗
Refer to pages 69, 70, and 81 for dimensions
when L6 and b are used for the calculation
formula.
∗
Refer to the reference pages shown in the table
to the right for dimensions that are not specifi ed
in each wiring specifi cation.
Calculation formula for dimensions
L1 = 11.5 x n1 + 15 x n2 + a + b x n3 + e
L2 = 11.5 x n1 + 15 x n2 + e + 93.7
M = (L1 + c)/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23
L4 = L3 − 10.5
L5 = (L3 − L1 + c)/2
L6 = b x n3 + 82
L7 = 15 x n2 + 41.5
n1: Number of valve stations of the JSY3000
n2: Number of ejector stations of the ZK2A
n3: Number of I/O units or input block stations
Coeffi cient
Reference
page
a
b
c
D-sub connector (IP40/Connector entry direction adjustable)
120.4
—
6.1
25
D-sub connector (IP67)
135.2
—
4.5
27
D-sub connector (IP20/Compact type)
133.4
—
6.1
31
Flat ribbon cable (IP40/Connector entry direction adjustable)
120.4
—
6.1
34
Flat ribbon cable (IP20/Compact type)
114.9
—
11.2
38
Spring type terminal block box
172.7
—
—
47
Terminal block box
194
—
—
51
Lead wire
141.7
—
—
59
Serial transmission: EX600 (M12 connector)
186.2
47
—
69
Serial transmission: EX600 (7/8 inch connector)
202.7
47
—
70
Serial transmission: EX245
217.8
54
—
75
Serial transmission: EX250
186.2
21
—
81
Serial transmission: EX260
133.4
—
—
89
Serial transmission: EX120
138.5
—
—
95
Coeffi cient
e
D side entry
—
U side/Both sides entry
23
Type
10
/
Side
Ported
Vacuum Unit ZK2 Combination Manifold
Stations
Stations
JSY3000
Series
124