![SMC Networks HRSH150-A*-20 Series Operation Manual Download Page 43](http://html1.mh-extra.com/html/smc-networks/hrsh150-a-20-series/hrsh150-a-20-series_operation-manual_1299256043.webp)
HRX-OM-Q026-B
Chapter 3 Transport and Setting Up
HRSH Series
3.4
Piping
3-25
How to connect piping
Tighten the piping to each connection as follows below.
Fig. 3-14 Tightening of piping
How to connect to the drain port
When piping the drain port, hold the ball valve of the drain port with a wrench
not to rotate it.
Fig. 3-15 Connection to the drain
Tank drain port
Hold the ball valve.
Without holding the ball valve of the drain port with a wrench, the ball
valve may rotate and it may cause a fluid leakage and malfunction of
the product. Be sure to hold the ball valve of the drain por
t.
Note: Incase of using the Y
strainer of the accessory, fasten
it on the return port.
Clean the filer of the strainer
after the trial operation before
the proper operation
Sealant
Y strainer
25A
Accessories
Barrel
nipple 25A
Sealant
Connetion port