-60-
EX
※※
-OMR1012
•[Module Properties] window is displayed. Perform each setting.
(1) Name: Input the description of specific unit.
(2) Comm Format: Select the data format of Connection Parameters.
(3) IP Address: Input IP Address which is set in SI unit.
(4) Assembly Instance: Set as below.
Description
Decimal
Common Format
“Data-INT”
“Data-SINT”
Input 100
100
Output 150
150
Configuration
105 105
(5) Size: Set as below.
Description
Decimal
Common Format
“Data-INT”
“Data-SINT”
Input
MIN. 1 word
MAX.32 words
MIN. 2 bytes
MAX.64 bytes
Output
MIN. 1 word
MAX.32 words
MIN. 2 bytes
MAX.64 bytes
Configuration 0
word 0
byte
: Select the setting depending on the existence of diagnostic data and the unit type connected.