12

13

Gener

al

3 positions

5 positions

Gener

al

Gener

al

3 positions

5 positions

Gener

al

Load

Load

Load

Load

Orange OUT2

Yellow OUT3

Green OUT4

Purple IN1

Gray IN2

White IN3

 install power supply

DC24V

Power supply for signal

DC24V

+
-

Brown DC1(+)

Blue DC2(-)

Pink OUT1

Brown DC2(+)

Blue DC1(-)

I/O cable

Power supply

cable

+
-

install power supply
switch

Main Circuit

+

-

DC24V

DC24V

+

-

Load

Load

Load

Load

Orange OUT2

Yellow OUT3

Green OUT4

Purple IN1

Gray IN2

White IN3

 install power supply

Power supply for signal

Brown DC1(+)

Blue DC2(-)

Pink OUT1

Brown DC2(+)

Blue DC1(-)

Power supply

cable

install power supply
switch

Main Circuit

I/O cable

•Corresponding to PNP I/O

•Corresponding to NPN  I/O

Power supply voltage

6mA or less / 1 circuit at DC24V(Photo-coupler input)

DC30V or less, 20mA or less / 1 circuit(opendrain output)

Input signal capacity

Output load capacity

Item

Specification

DC24V 10%

Max.5A(within 2s) normally 2.5A at DC24V

Power supply
for drive

Power supply
for signal

Emergency stop, Abnormal external output,Abnormal power supply, 
Abnormal drive,Abnormal temperature, Abnormal stroke,
Abnormality of motor, Abnormality of controller

Abnormal detection items

Current consumption

Current consumption

DC24V 10%

30mA output load capacity at DC24V

Power supply voltage

Symbol

Cable color

Signal name

Content

DC1(+)

Brown

Vcc

Power supply cable for actuator oper-
ation

DC1(-)

Blue

GND

Power supply cable 2 wire

I/O cable 9 wire

AWG20(20 wire/ 0.16mm

2

)

AWG28(7 wire/ 0.127mm

2

)

Example of Internal Circuit and Wiring

•The product can be used without connection of I/O cable, but in that case, consider the

safety and install power supply switch for drive. And for emergency case, turn off the switch.

Cable color

Brown

Blue

Pink

Orange

Yellow

Green

Purple

DC2(+)

DC2(-)

OUT1

OUT2

OUT3

OUT4

IN1

Grey

IN2

White

IN3

Signal name

Vcc

GND

READY output

The output for completion of positioning 1

The output for completion of positioning 2

Alarm output

The input transmit drive command 1

The input transmit drive command 2

Emergency stop input

Content

Power supply line for signal

The signal to show the controller can be operated 

The signal to show the positioning is
completed

The signal to show the alarm occurs

The signal to transmit drive command

The signal to transmit emergency stop
command(When contact is opened)

Symbol

Electric Specification

Summary of Contents for e-Rodless E-MY2 Series

Page 1: ...e Rodless Actuator E MY2 Series Operation Manual URL http www smcworld com...

Page 2: ...INLAND 358 9 859 580 PORTUGAL 351 2 610 89 22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 134...

Page 3: ...cause injury Do not disassemble remodel including change of printed circuit board or repair An injury or failure can result Do not operate beyond specification range Fire malfunction or switch damage...

Page 4: ...re cycle Do not use where close to surge generating source Do not short the load Short of the load of the controller is indicated as error but it may cause over current and break the actuator Do not p...

Page 5: ...er FG terminal Motor side End side Names and Functions of Individual Parts Controller integrated type Encoder cable of the controller I O cable Encoder connecting connector Motor connecting connector...

Page 6: ...5 Tightening torgue 1 3 to 1 4N m L type bracket Controller Motor Mounting screw M4 Mounting by L type bracket Mount the optional L type bracket on the main unit using the two mounting screws M5X8L an...

Page 7: ...ch to move the actuator to intermediate position and set the intermediate position The switch to move the work to motor end The switch to move the work to the other end The rotary switch to set moving...

Page 8: ...bnormal stroke Abnormality of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol C...

Page 9: ...Command to operate motor side Command to operate end side Command to operate intermediate stop IN2 Symbol Connection of the motor and the controller When controller separated type is used Mind the dir...

Page 10: ...ush of over 3s at least the product comes into learning mode and starts stroke learning 3 2 Confirm 2 indicator lamps MOTOR and END are lighting Since the actuator starts moving automatically to learn...

Page 11: ...switch and the speed of actuator is set Rotary switch to set speed of movement to the direction of the motor side Rotary switch to set speed of movement to the direction of the end side 6 2 Setting of...

Page 12: ...esistance Noise resistance Between external terminal and case 50 M 500 VDC 1000 Vp p Pulse width 1 s Rise time 1 ns Acquired certified standard CE marking Model E MY2C E MY2H E MY2HT Item Specificatio...

Page 13: ...Red Power is turn on Symbol When positioning completed External input stop completed Motor side End side Intermediate 1 Intermediate 2 Intermediate 3 In case of alarm 2 State of indicator light light...

Page 14: ...y of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol Cable color Signal name Co...

Page 15: ...intermediate stop 1 Command to operate intermediate stop 2 Command to operate intermediate stop 3 External input stop command IN2 IN3 Symbol Example of Internal Circuit and Wiring continue Connection...

Page 16: ...at the center of the stroke Press again within 3s after pressing Press within 3s after pressing Press within 3s after pressing Travel to intermediate position 1 Travel to intermediate position 2 Trav...

Page 17: ...moved the intermediate position is changed On the other hand change of the position of the stroke adjusting unit at stroke does not make sense If the stroke is set shorter than the distance between th...

Page 18: ...not turn off input of drive command until READY output is confirmed The signal for completion of positioning is output when the actuator reaches the position 0 5mm before target position indicated as...

Page 19: ...drain output Input signal capacity Output load capacity Item Specification DC24V 10 Max 5A within 2s normally 2 5A at DC24V Power supply for drive Power supply for signal Emergency stop Abnormal exter...

Page 20: ...m alarm reset Abnormal drive Max output is continued for prolonged period Check the weight of work and foreign material attached to actuating part and then perform alarm reset Tuming off Ligting blink...

Page 21: ...om alarm condition Alarm output Longer than 50ms Emergency stop input READY output contact is opened External alarm reset Even if alarm occurs it recovers from alarm condition by inputting emergency s...