background image

Thank you for purchasing the SMC E-MY2 Series e-Rodless Actuator.
Please read this manual carefully before operating the e-Rodless Actuator and make sure
you understand the e-Rodless Actuator, 
its capabilities and limitations.
Please keep this manual handy for future reference.

OPERATOR

• This operation manual has been written for those who have knowledge of machinery and

apparatuses that use actuator and have full knowledge of assembly, operation and
maintenance of such equipment.

• Please read this operation manual carefully and understand it before assembling,

operating or providing maintenance service to the actuator.

Phone

AUSTRIA / (43) 2262-62 280

ITALY / (39) 02-92711

BELGIUM / (32) 3-355 1464

NETHERLANDS / (31) 20-531 8888

CZECH REP. / (420) 5-414 24611

NORWAY / (47) 67 12 90 20

DENMARK / (45) 70 25 29 00

POLAND / (48) 22-548 50 85

FINLAND / (358) 9-859 580

PORTUGAL / (351) 2 610 89 22

FRANCE / (33) 1-64 76 1000

SPAIN / (34) 945-18 4100

GERMANY / (49) 6103 4020 

SWEDEN / (46) 8-603 0700

GREECE / (30) 1- 342 6076

SWITZERLAND / (41) 52-396 3131

HUNGARY / (36) 1-371 1343

TURKEY / (90) 212 221 1512

IRELAND / (353) 1-403 9000

UNITED KINGDOM / (44) 1908-56 3888

SAFETY

2

Model Indication Method

5

Names and Functions of Individual Parts

6

Installation

9

3 positions

Names and Functions of Controller

11

Example of Internal Circuit and Wiring

12

Setting

15

Operation Characteristics

20

Specifications

21

5 positions

Names and Functions of Controller

23

Example of Internal Circuit and Wiring

24

Setting

27

Operation Characteristics

32

Other Functions

33

Specifications

34

Common Functions

Lock function

35

Alarm indication and remedy

36

Alarm reset

38

CONTENTS

General

General

3

positions

5

positions

To facilitate recycling, this
manual is printed using
biodegradable soy ink, which
can easily be de-inked.

This manual is printed in the
"non-water system", which does
not output toxic liquid waste.

Summary of Contents for e-Rodless E-MY2 Series

Page 1: ...e Rodless Actuator E MY2 Series Operation Manual URL http www smcworld com...

Page 2: ...INLAND 358 9 859 580 PORTUGAL 351 2 610 89 22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 134...

Page 3: ...cause injury Do not disassemble remodel including change of printed circuit board or repair An injury or failure can result Do not operate beyond specification range Fire malfunction or switch damage...

Page 4: ...re cycle Do not use where close to surge generating source Do not short the load Short of the load of the controller is indicated as error but it may cause over current and break the actuator Do not p...

Page 5: ...er FG terminal Motor side End side Names and Functions of Individual Parts Controller integrated type Encoder cable of the controller I O cable Encoder connecting connector Motor connecting connector...

Page 6: ...5 Tightening torgue 1 3 to 1 4N m L type bracket Controller Motor Mounting screw M4 Mounting by L type bracket Mount the optional L type bracket on the main unit using the two mounting screws M5X8L an...

Page 7: ...ch to move the actuator to intermediate position and set the intermediate position The switch to move the work to motor end The switch to move the work to the other end The rotary switch to set moving...

Page 8: ...bnormal stroke Abnormality of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol C...

Page 9: ...Command to operate motor side Command to operate end side Command to operate intermediate stop IN2 Symbol Connection of the motor and the controller When controller separated type is used Mind the dir...

Page 10: ...ush of over 3s at least the product comes into learning mode and starts stroke learning 3 2 Confirm 2 indicator lamps MOTOR and END are lighting Since the actuator starts moving automatically to learn...

Page 11: ...switch and the speed of actuator is set Rotary switch to set speed of movement to the direction of the motor side Rotary switch to set speed of movement to the direction of the end side 6 2 Setting of...

Page 12: ...esistance Noise resistance Between external terminal and case 50 M 500 VDC 1000 Vp p Pulse width 1 s Rise time 1 ns Acquired certified standard CE marking Model E MY2C E MY2H E MY2HT Item Specificatio...

Page 13: ...Red Power is turn on Symbol When positioning completed External input stop completed Motor side End side Intermediate 1 Intermediate 2 Intermediate 3 In case of alarm 2 State of indicator light light...

Page 14: ...y of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol Cable color Signal name Co...

Page 15: ...intermediate stop 1 Command to operate intermediate stop 2 Command to operate intermediate stop 3 External input stop command IN2 IN3 Symbol Example of Internal Circuit and Wiring continue Connection...

Page 16: ...at the center of the stroke Press again within 3s after pressing Press within 3s after pressing Press within 3s after pressing Travel to intermediate position 1 Travel to intermediate position 2 Trav...

Page 17: ...moved the intermediate position is changed On the other hand change of the position of the stroke adjusting unit at stroke does not make sense If the stroke is set shorter than the distance between th...

Page 18: ...not turn off input of drive command until READY output is confirmed The signal for completion of positioning is output when the actuator reaches the position 0 5mm before target position indicated as...

Page 19: ...drain output Input signal capacity Output load capacity Item Specification DC24V 10 Max 5A within 2s normally 2 5A at DC24V Power supply for drive Power supply for signal Emergency stop Abnormal exter...

Page 20: ...m alarm reset Abnormal drive Max output is continued for prolonged period Check the weight of work and foreign material attached to actuating part and then perform alarm reset Tuming off Ligting blink...

Page 21: ...om alarm condition Alarm output Longer than 50ms Emergency stop input READY output contact is opened External alarm reset Even if alarm occurs it recovers from alarm condition by inputting emergency s...