background image

"   " indicates light is on, "   " indicates light is off.

1  See page 36, 37 and after for ALM display in case of error.

3 positions

Names and Functions of Controller

11

Example of Internal Circuit and Wiring

12

Setting

15

Operation Characteristics

20

Specifications

21

10

11

Gener

al

3 positions

5 positions

Gener

al

Gener

al

3 positions

5 positions

Gener

al

Names and Functions of Controller (3 positions)

1

2

3

4

5

6

7

8

A

C

E

D

B

Switch

Controller detail

Display of the indicator lamp and basic operation

Description

MIDDLE indicator lamp(Green)

MOTOR indicator lamp(Green)

END indicator lamp(Green)

PWR indicator lamp(Green)

ALM indicator lamp(Red)

Power is 

turn on

Symbol

When positioning completed

Motor side

End side

Intermediate

In case of

error

1

3 positions

State of 

indicator light

light

goes out

blink

lighting

No.

Content/Function

Stroke learning switch

The switch to move the actuator to intermediate position and set the intermediate position

The switch to move the work to motor end

The switch to move the work to the other end

The rotary switch to set moving speed to motor end

The rotary switch to set moving speed to the other end

The rotary switch to set moving acceleration to motor end

The rotary switch to set moving acceleration to the other end

Note) Refter to the catalog for Stroke, Auto switch and Number of auto switches.

E-MY2  C   16

100

TA

N

M

M9B

Positioning stop number

Nil

3 positions

Nominal size

16

25

Stroke

Auto switch

Number of

auto switches

Cable length

Nil

M

L

Z

Controller integrated type

Controller

separated

type

1m

3m

5m

Motor placement

TA

DA

TB

DB

On the top, (left)

On the bottom, (left)

On the top, (right)

On the bottom, (right)

Output type

N

NPN

P

PNP

Speed type

L

M

Nil

Low speed

Medium speed

Standard speed

Load type

Q

Nil

E

D

Heavy load

Standard load

Medium load

Light load

H

High speed

Guide Type

C

Cam follower guide type

H

Linear guide

single axis type

HT

Linear guide

double axis type

Summary of Contents for e-Rodless E-MY2 Series

Page 1: ...e Rodless Actuator E MY2 Series Operation Manual URL http www smcworld com...

Page 2: ...INLAND 358 9 859 580 PORTUGAL 351 2 610 89 22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 134...

Page 3: ...cause injury Do not disassemble remodel including change of printed circuit board or repair An injury or failure can result Do not operate beyond specification range Fire malfunction or switch damage...

Page 4: ...re cycle Do not use where close to surge generating source Do not short the load Short of the load of the controller is indicated as error but it may cause over current and break the actuator Do not p...

Page 5: ...er FG terminal Motor side End side Names and Functions of Individual Parts Controller integrated type Encoder cable of the controller I O cable Encoder connecting connector Motor connecting connector...

Page 6: ...5 Tightening torgue 1 3 to 1 4N m L type bracket Controller Motor Mounting screw M4 Mounting by L type bracket Mount the optional L type bracket on the main unit using the two mounting screws M5X8L an...

Page 7: ...ch to move the actuator to intermediate position and set the intermediate position The switch to move the work to motor end The switch to move the work to the other end The rotary switch to set moving...

Page 8: ...bnormal stroke Abnormality of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol C...

Page 9: ...Command to operate motor side Command to operate end side Command to operate intermediate stop IN2 Symbol Connection of the motor and the controller When controller separated type is used Mind the dir...

Page 10: ...ush of over 3s at least the product comes into learning mode and starts stroke learning 3 2 Confirm 2 indicator lamps MOTOR and END are lighting Since the actuator starts moving automatically to learn...

Page 11: ...switch and the speed of actuator is set Rotary switch to set speed of movement to the direction of the motor side Rotary switch to set speed of movement to the direction of the end side 6 2 Setting of...

Page 12: ...esistance Noise resistance Between external terminal and case 50 M 500 VDC 1000 Vp p Pulse width 1 s Rise time 1 ns Acquired certified standard CE marking Model E MY2C E MY2H E MY2HT Item Specificatio...

Page 13: ...Red Power is turn on Symbol When positioning completed External input stop completed Motor side End side Intermediate 1 Intermediate 2 Intermediate 3 In case of alarm 2 State of indicator light light...

Page 14: ...y of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol Cable color Signal name Co...

Page 15: ...intermediate stop 1 Command to operate intermediate stop 2 Command to operate intermediate stop 3 External input stop command IN2 IN3 Symbol Example of Internal Circuit and Wiring continue Connection...

Page 16: ...at the center of the stroke Press again within 3s after pressing Press within 3s after pressing Press within 3s after pressing Travel to intermediate position 1 Travel to intermediate position 2 Trav...

Page 17: ...moved the intermediate position is changed On the other hand change of the position of the stroke adjusting unit at stroke does not make sense If the stroke is set shorter than the distance between th...

Page 18: ...not turn off input of drive command until READY output is confirmed The signal for completion of positioning is output when the actuator reaches the position 0 5mm before target position indicated as...

Page 19: ...drain output Input signal capacity Output load capacity Item Specification DC24V 10 Max 5A within 2s normally 2 5A at DC24V Power supply for drive Power supply for signal Emergency stop Abnormal exter...

Page 20: ...m alarm reset Abnormal drive Max output is continued for prolonged period Check the weight of work and foreign material attached to actuating part and then perform alarm reset Tuming off Ligting blink...

Page 21: ...om alarm condition Alarm output Longer than 50ms Emergency stop input READY output contact is opened External alarm reset Even if alarm occurs it recovers from alarm condition by inputting emergency s...

Reviews: