4 SPECIFICATION
Parameter
Details
Working Voltage
DC8. 0V to 35. 0V, uninterruptible power supply
Overall Consumption
<5W (Standby mode: ≤2W)
Voltage Input:
3 Phase 4 Wire
3 Phase 3 Wire
Single Phase 2 Wire
2 Phase 3 Wire
DC
AC 20V - 360V (ph-N)
AC 30V - 600V (ph-ph)
AC 20V - 360V (ph-N)
AC 20V - 360V (ph-N)
DC 0V - 75V (ph-N)
Alternator Frequency
50Hz/60Hz
Speed Sensor Voltage
1. 0 V to 24 V (RMS)
Speed Sensor Frequency
Maximum 10,000 Hz
Start Relay Output
8A DC28V power supply output
Fuel Relay Output
8A DC28V power supply output
Configurable Relay Output 1 8A DC28V power supply output
Configurable Relay Output 2 8A DC28V power supply output
Configurable Relay Output 3 8A DC28V power supply output
Configurable Relay Output 4 8A AC250V free volt output
Light Control Relay Output
1~4
8A AC250V free volt output (total output current: 8A)
If 1~4 is all used, the maximum current of each light is 2A.
Light Control Relay Output
5~8
8A AC250V free volt output (total output current: 8A)
If 1~4 is all used, the maximum current of each light is 2A.
Case Dimensions
197 mm x 152 mm x 47 mm
Panel Cutout
186mm x 141mm
CT Secondary Current
DC Current Input
Rated: 5A
Hall sensor’s secondary side current: (4~20)mA
Working Conditions
Temperature: (-25~+70)°C
Relative Humidity: (20~93)%RH
Storage Conditions
Temperature:(-25~+70)°C
Protection Level
IP55. If water-proof gasket is inserted between panel and
enclosure.
Insulation Intensity
Apply AC2.2kV voltage between high voltage terminal and
low voltage terminal;
The leakage current is not more than 3mA within 1min.
Weight
0.71kg