ALC700 Series Light Tower Set Controller
ALC700 Series Light Tower Set Controller 2018-03-02 Version 1.4 Page 17 of 51
5.5 AUTO SMS MODE
A.
Press
,
its indicator light on, and controller enters
Auto
mode. Meanwhile, the panel
display Auto Mode Select (Fig 1); Press
and
to select 02 Auto SMS Mode and
press
or
to confirm (Fig 2).
B.
When SMS message module receives the start command, light tower set begin cranking
and flashlight is twinkling (if configured). Stop delay will be displayed twinklingly on the first
line of the second screen. (Fig 3).
C.
If generator voltage and frequency has reached on-load requirements (Voltage
≥ on-load
voltage and frequency
≥ on-load frequency), all the lights will illuminate in proper order and
the illumination interval delay is 2s (can be set as 1~300s). (Fig 4,5)
Fig 1
Fig 2
AUTO DIAL-UP MODE
WAIT SMS COMMAND
CURRENT TIME 12:05:18
GENERATOR AT REST
Fig 3
AUTO DIAL-UP MODE
SMS START
CURRENT TIME 12:05:18
CRANKING 5s
Fig 4
AUTO DIAL-UP MODE
SMS START
CURRENT TIME 16:32:18
2# OFF DELAY 09s
AUTO DIAL-UP MODE
SMS START
CURRENT TIME 16:33:58
GENERATOR NORMAL RUNNING
Fig 5
AUTO MODE SELECT
01 AUTO TIMER MODE
02 AUTO SMS MODE
03 SUNRISE/SUNSET MODE