![Smartgen ALC700 SERIES User Manual Download Page 44](http://html.mh-extra.com/html/smartgen/alc700-series/alc700-series_user-manual_1297472044.webp)
ALC700 Series Light Tower Set Controller
ALC700 Series Light Tower Set Controller 2018-03-02 Version 1.4 Page 44 of 51
8.12 SMS (ORDER AND REPLY)
No.
SMS Code
Description
1 SMS STOP
Stop mode order; set controller into stop mode; Stop
running light tower set;
Reply
:
SMS STOP OK
2 SMS START
Start order; can control light tower set to start;
Reply
:
SMS START OK
3
SMS SUNRISE/SET
START
Sunrise/sunset mode order
Reply
:
SMS SUNRISE/SET START OK
4
SMS TIME SET
13-01-04 20:13:14
Set the time of controller;
Set form
:
YY-MM-DD HH:MM:SS
Reply
:
TIME SET OK YY-MM-DD HH:MM:SS
5 SMS GENSET
Inquiry order; inquiry the current status of controller.
Reply
:
GENSET AT REST or
GENSET IS RUNNING
YY-MM-DD HH:MM:SS
6 SMS ENGINE
Inquiry all sensors
’ information
Reply
:
all sensors
’ information and the real time
7 SMS OPS
Inquiry oil pressure sensor
’s information
Reply
:
oil pressure
8 SMS WTP
Inquiry temperature sensor
’s information
Reply
:
engine temperature
9 SMS FLE
Inquiry fuel level sensor
’s information
Reply
:
fuel level sensor
’s information
NOTE: Its national and area
’s cods must be added, e.g. Chinese number should be set as
+8613666666666 or
008613666666666
.
NOTE
:
The SMS orders are active only when GSM modem is enabled. In addition, the
1~3 SMS orders are active only in AUTO DIAL-UP MODE.
NOTE
:
The controller will send alarm information to preset telephone automatically when
shutdown alarm or trip alarm occur.
8.13 SUNRISE/SET SET
Users can select corresponding city or define city
’s information (longitude, latitude and time
zone) via utility software and download the information into controller; then controller will run in
auto sunrise/set mode.
NOTE
:
The information can be configured by software via PC only.