ACC4100 Diesel Air Compressor Controller User Manual Page 28 of 52
No.
Item
Range
Default
Description
1: Normally Close
Alternate Configuration Setting
Alternate Configuration 1
1
Enable Choose
(0-1)
0
0: Disable 1: Enable
2
Engine Rated Speed
(0-6000)r/min 2200
When this is enabled, if input is configured
to “Alt Config. 1 Active”, and if input is
active, speed shall be adjusted according
to alternate configuration settings after
load.
3
Engine Unload Speed
(0-100.0)%
70.0
4
Air
Com.
Rated
Pressure
(0-30000)kPa 700
5
Air Com. Unload Act
Press
(0-30000)kPa 600
Alternate Configuration 2
1
Enable Choose
(0-1)
0
0: Disable 1: Enable
2
Engine Rated Speed
(0-6000)r/min 2200
When this is enabled, if input is configured
to “Alt Config. 2 Active”, and if input is
active, speed shall be adjusted according
to alternate configuration settings after
load.
3
Engine Unload Speed
(0-100.0)%
70.0
4
Air
Com.
Rated
Pressure
(0-30000)kPa 700
5
Air Com. Unload Act
Press
(0-30000)kPa 600
Alternate Configuration 3
1
Enable Choose
(0-1)
0
0: Disable 1: Enable
2
Engine Rated Speed
(0-6000)r/min 2200
When this is enabled, if input is configured
to “Alt Config. 3 Active”, and if input is
active, speed shall be adjusted according
to alternate configuration settings after
load.
3
Engine Unload Speed
(0-100.0)%
70.0
4
Air
Com.
Rated
Pressure
(0-30000)kPa 700
5
Air Com. Unload Act
Press
(0-30000)kPa 600
Maintenance Setting
1
Oil Filter Set
(0-1)
0
0: Disable 1: Enable
Maintenance time, maintenance time due
action, maintenance timing method,
maintenance time reset can also be set at
the same time; After maintenance,
maintenance time due alarm can be
removed by resetting maintenance time;
Please refer to Table 14 for details.
2
Oil Separator Set
(0-1)
0
3
Air Filter Set
(0-1)
0
4
Lubrication Set
(0-1)
0
5
Engine Oil Filter Set
(0-1)
0
6
Engine Fuel Filter Set
(0-1)
0
7
Engine Lubrication Set
(0-1)
0
8
Maintenance 8 Set
(0-1)
0
9
Maintenance 9 Set
(0-1)
0
10
Maintenance 10 Set
(0-1)
0
NOTES
:
—
Regarding parameter setting on PC software, it isn't needed to input default factory password “1234” if not changed;
if it is the first time to do configuration on PC, then it is needed to input module password in password screen;
—
Digital input ports cannot be set the same items (except for user-defined). Otherwise function shall not work
correctly; Output ports can be set the same item;
—
Engine temperature related settings: if it is ordinary engine and engine temperature is needed, any one of flexible
sensors 1~4 shall be set engine temperature sensor; and at the same time curve type shall be set the