ACC4100 Diesel Air Compressor Controller User Manual Page 29 of 52
corresponding one; Next is to set engine temperature related sensor; Select corresponding flexible sensor, which is
engine temperature sensor at this time, heater control and cooler control can be realized. If alarm output function
will be set, corresponding flexible sensor output shall be set;
—
Engine oil pressure related settings: if it is conventional engine and it is needed to use engine oil pressure to judge
crank disconnect, if it is ordinary engine and it is needed to use engine oil pressure to judge crank disconnect, any
one of the flexible sensors 1~4 shall be set engine oil pressure, meanwhile curve type shall be set to the
corresponding one. Then set engine oil pressure related sensor; Choose corresponding sensor, and at this time oil
pressure is displayed, which can be one of the crank disconnect conditions; if alarm output function will be set,
corresponding flexible sensor output shall be set;
—
Discharge temperature display related settings: if discharge temperature is needed to display in the first page of main
screen, then any one of the flexible sensors 1~4 shall be set temperature, and at the same time curve type shall be set
corresponding curve; Then set discharge temperature display related setting; Choose corresponding sensor, and at this
time first page shall have discharge temperature. If alarm output function will be set, corresponding flexible sensor output
shall be set.
8.2
DEFINABLE CONTENTS OF AUXILIARY OUTPUT PORTS 1~6
8.2.1
DEFINABLE CONTENTS OF AUXILIARY OUTPUT PORTS 1~6
Table 10 Definable Contents of Auxiliary Output Ports 1~6
No.
Type
Function Description
0
Not Used
1
Custom Period 1
Please refer to the following contents for function details.
2
Custom Period 2
3
Custom Period 3
4
Custom Period 4
5
Custom Period 5
6
Custom Period 6
7
Custom Combined 1
8
Custom Combined 2
9
Custom Combined 3
10
Custom Combined 4
11
Custom Combined 5
12
Custom Combined 6
13
Reserved
14
Reserved
15
Air Flap Control
Act at the time of over speed shutdown alarm and emergency
stop; Air flap can be closed to realize fast stop.
16
Audible Alarm
Act at the time of warning and shutdown alarms; Announciator
can be connected externally; It can be inhibited to output when
input port “Alarm Mute” is active or any key is pressed; When
there is new warning or shutdown alarm, it outputs again.
17
Louver Control
Act at the time of engine start; Disconnect after engine stop.
18
Fuel Pump Control
Act by fuel pump control upper and lower limits of fuel level
sensor.
19
Heater Control
Act by heater control upper and lower limits of temp. sensor.