ACC4100 Diesel Air Compressor Controller User Manual Page 13 of 52
5.2
PANEL ICON DESCRIPTION OF DPF REGENERATION
Table 5 DPF Regeneration Panel Icon Description
Icon
Description
Engine fault indicator
NCD state indicator
DPF discharge temperature indicator
DPF manual regeneration request indicator
DPF regeneration inhibition indicator
DPF regeneration response indicator
5.3
DPF MANUAL REGENERATION OPERATION
Configure an input port and set it to “DPF Manual Regeneration Request”, and connect a button
(not self-lock) externally.
Press
on controller panel and enter parameter setting menu. Press
and select “DPF
Regeneration”, and press
again to enter DPF regeneration. Controller display is as Fig. 3:
Fig. 3 DPF Regeneration
When manual regeneration is needed, press “DPF Manual Regeneration Request” button. On DPF
panel, DPF response indicator is light on, and it enters DPF regeneration preparation status. When
request indicator is always illuminated on the panel, and response indicator flashes at the same time
(once per second), it means that regeneration preparation is well. Controller display is as Fig. 4: