CHAPTER 6
TROUBLESHOOTING
45
smarttech.com/kb/170819
Standby light
Interactive flat panel
status
Issues
Solutions
Solid amber
Standby mode
The interactive flat panels
don’t turn on when
participants enter the room.
l
Enable presence detection (see
page 65).
l
Reduce the room temperature to
increase the difference between
the ambient temperature and
human body temperature.
l
Ask participants to move closer to
the interactive flat panels or make
bigger motions.
l
Remove any glass, acrylic or other
material between participants and
the presence detection sensors.
The interactive flat panels
are turning on after they’ve
been turned off.
l
Increase the re-enable time, which
is the interval before the presence
detection sensors start detecting
motion again.
l
Close any blinds or shades to
prevent sunlight from hitting the
presence detection sensors.
The interactive flat panels
are turning on when
participants aren’t present.
l
Remove sources of major
temperature fluctuation (humidifier
emission, air conditioning, heating
system).
l
Close any blinds or shades to
prevent sunlight from hitting the
presence detection sensors.