Firmware Upgrade
COMX-P2020 Module Installation and Use (6806800K97F)
85
Scanning PCI bus 03
03 00 18ca 0027 0300 00
PCIE1 on bus 02 - 03
In: serial
Out: serial
Err: serial
Net: eTSEC1, eTSEC2, eTSEC3
Hit any key to stop autoboot: 0
=>
4.
Set the u-Boot environment variables for the network settings through the terminal:
=> setenv ethaddr 00:01:af:12:23:01
=> setenv ipaddr 192.168.0.253
=> setenv netmask 255.255.255.0
=> setenv gatewayip 192.168.0.1
=> setenv serverip 192.168.0.197
=> setenv ethact eTSEC1
=> ping 192.168.0.197
Enet starting in 100BT/FD
Speed: 100, full duplex
Using eTSEC1 device
host 192.168.0.197 is alive
5.
Set the U-Boot environment variables for upgrade files and upgrade the SPI Flash. This
step may take up to 1 minute.
=> setenv tftppath COMX-P2020/current
=> setenv uboot_spi u-boot-spi.bin
=> run upgradespi
4096 KiB S25FL032A(P) at 0:0 is now current device
Enet starting in 100BT/FD
Speed: 100, full duplex
Using eTSEC1 device
TFTP from server 192.168.0.197; our IP address is 192.168.0.250
Filename 'COMX-P2020/current/u-boot-spi.bin'.
Load address: 0x1000000
Loading: ####################################
Summary of Contents for COMX-P2020 BSP
Page 1: ...COMX P2020 Module Installation and Use P N 6806800K97F November 2019 ...
Page 6: ...6 ProductNameLong Manual Type 680xxxxxxx Table of Contents ...
Page 8: ...List of Tables 8 ProductNameLong Manual Type 680xxxxxxx ...
Page 10: ...List of Figures 10 ProductNameLong Manual Type 680xxxxxxx ...
Page 28: ...28 COMX P2020 Module Installation and Use 6806800K97F Introduction Introduction ...
Page 61: ...Controls LEDs and Connectors COMX P2020 Module Installation and Use 6806800K97F 61 ...
Page 63: ...Controls LEDs and Connectors COMX P2020 Module Installation and Use 6806800K97F 63 ...
Page 65: ...Controls LEDs and Connectors COMX P2020 Module Installation and Use 6806800K97F 65 ...
Page 91: ...1 ...