COMX-P2020 Module Installation and Use (6806800K97F)
81
Chapter 6
Firmware Upgrade
6.1
Upgrade Procedure
6.1.1
Host Setup
Host setup is very critical in upgrading the firmware. The following instructions are generic,
and have been tested at RHEL 4.6 and RHEL 5.3 - 32 bit. Your system may be different
and the commands should be adjusted accordingly.
1. Turn off the firewall for tftp to work. Type iptables -F or setup at the command line.
2.
All the operators on the host side should be ordinary users which have "sudo" privilege
with NO password. To obtain "sudo" privilege, the operator should login as root, and
run "visudo" and add the below line at the end.
Example:
ec7987 ALL=(ALL) NOPASSWD: ALL
3.
Setting up the tftp service:
Create the /local/tftpboot/COMX-P2020/current directory at host, and copy the
release file: COMX-P2020.bsp.tar.gz to the directory:
/local/tftpboot/COMX-P2020/current
[percy@localhost current]$ sudo chmod 777
/local/tftpboot/COMX-P2020/current
[percy@localhost current]$ ls -al COMX-P2020.bsp.tar.gz
-rwxr--r-- 1 percy percy 462501957 Dec 9 14:57 COMX-
P2020.bsp.tar.gz
[percy@localhost current]$
Extract all the BSP targets from the COMX-P2020.bsp.tar.gz:
[percy@localhost current]$ tar zxvf COMX-P2020.bsp.tar.gz
[percy@localhost current]$ ls -al
total 910224
drwxr-xr-x 2 percy percy 4096 Dec 10 09:37 .
drwxrwxr-x 8 percy percy 4096 Dec 9 18:07 ..
-rw-r--r-- 1 percy percy 9824 Dec 9 14:51 comx.dtb
Summary of Contents for COMX-P2020 BSP
Page 1: ...COMX P2020 Module Installation and Use P N 6806800K97F November 2019 ...
Page 6: ...6 ProductNameLong Manual Type 680xxxxxxx Table of Contents ...
Page 8: ...List of Tables 8 ProductNameLong Manual Type 680xxxxxxx ...
Page 10: ...List of Figures 10 ProductNameLong Manual Type 680xxxxxxx ...
Page 28: ...28 COMX P2020 Module Installation and Use 6806800K97F Introduction Introduction ...
Page 61: ...Controls LEDs and Connectors COMX P2020 Module Installation and Use 6806800K97F 61 ...
Page 63: ...Controls LEDs and Connectors COMX P2020 Module Installation and Use 6806800K97F 63 ...
Page 65: ...Controls LEDs and Connectors COMX P2020 Module Installation and Use 6806800K97F 65 ...
Page 91: ...1 ...