LD290
– Operation and Maintenance Instruction Manual
5.6
MODEL
GAGE PRESSURE TRANSMITTER (CONTINUATION)
LD290M CODE Special Procedure
C1
Degrease Cleaning (Oxygen or Chlorine Service)
CODE
Output Signal
G0
G1
4-20 mA
0-20 mA
CODE
Housing Material (7)
H0
H1
H2
Aluminum (IP/TYPE)
316 SST (IP/TYPE)
Aluminum for Saline Atmosphere (IPW/TYPEX)
(6)
R
H3
H4
316 SST for Saline Atmosphere (IPW/TYPEX)
(6)
Copper Free Aluminum (IPW/TYPEX)
(6)
CODE
Identification Plate
I1
I4
I5
I6
I7
FM: XP, IS, NI, DI
EXAM (DMT): Ex-ia; NEMKO: Ex-d
CEPEL: Ex-d, Ex-ia
Without Certification
EXAM (DMT) Grupo I, M1 Ex-ia
IC
IF
IJ
IO
IR
IECEX MINING
IECEX
NEMKO
– EEX-D
CEPEL (COMBUSTIBLE DUST)
TIBR CJSC - GOST RUSSIA: EX-D, EX-IA
CODE
Painting
P0
P1
P2
P3
Munsell N 6,5 Gray
Blue Safety N4845 (standard 1374 Petrobras)
Blue Safety N4845 (standard 1735 Petrobras)
Polyester Black
P8
P9
Without Painting
Blue Safety Base Epoxy
– Electrostatic Painting
CODE Manufacturing Standard
S0
S5
SMAR
BASF
CODE Display Unit
0
Y1
Y2
Y3
Y0
Y1
Y2
Y3
Percentage
Display 1: Current (mA)
Display 1: Pressure (Eng. Unit)
Display 1: Temperature (ºC)
Y4
Y5
Y6
YU
Display 2: Current (mA)
Display 2: Pressure (Eng. Unit)
Display 2: Temperature (ºC)
Y
User’s specification
(5)
CODE Tag Plate
J0
J1
With TAG
Without TAG
J2
User’s specification
CODE Burn Out
BD
Down scale
BU
Up scale
CODE Special Options
ZZ
Special
– See notes
LD290M
*
G0
H0
I1
P0
S0
Y0**
J0
BD
Typical Model Number
*
Leave blank for no special procedure
**
Can choose 1 option for each Display (1 and 2)
NOTES
(1)
Meets NACE material recommendation per MR-01-75.
(2
) Inert fluid: safe for oxygen service.
(3)
Standard DIN16288 was replaced by DIN EN 837-1.
(4)
Thread PG13.5 certified Ex-d in CEPEL.
Threads ½ BSP ¾ BSP and Z (user option) is not certified Ex-d.
(5)
Limited values to 4 1/2 digits; limited unit to 5 characters.
(6)
IPW/TYPEX was tested for 200 hours.
(7)
IPX8 tested for 10 meters of water column for 24 hours.
Summary of Contents for LD290
Page 1: ......
Page 2: ......
Page 6: ...LD290 Operation and Maintenance Instruction Manual VI...
Page 9: ...Installation 1 3 Figure 1 1 b Dimensional Drawing and Mounting Position for LD290 Sanitary...
Page 11: ...Installation 1 5 Figure 1 1 d Dimensional Drawing and Mounting Position for LD290 Level...
Page 18: ...LD290 Operation and Maintenance Instruction Manual 1 12...
Page 32: ...LD290 Operation and Maintenance Instruction Manual 3 10...
Page 42: ...LD290 Operation and Maintenance Instruction Manual 4 10...
Page 61: ...Appendix A A 7 CEPEL Centro de Pesquisa de Energia El trica...
Page 62: ...LD290 Certifications Information A 8...
Page 63: ...Appendix A A 9 FM Approvals...
Page 64: ...LD290 Certifications Information A 10...
Page 66: ...LD290 Appendix B B 2...