![SMAR LD290 Operation And Maintance Manual Download Page 52](http://html1.mh-extra.com/html/smar/ld290/ld290_operation-and-maintance-manual_1294937052.webp)
LD290
– Operation and Maintenance Instruction Manual
5.10
MODEL
LOW COST FLANGED PRESSURE TRANSMITTER (CONTINUATION)
LD290L
CODE Special Procedure
C1
Degrease Cleaning (Oxygen or Chlorine Service)
CODE
Output Signal
G0
G1
4-20 mA
0-20 mA
CODE
Housing Material (9)
H0
H1
H2
Aluminum (IP/TYPE)
316 SST (IP/TYPE)
Aluminum for saline atmosphere (IPW/TYPEX)
(8)
H3
H4
R
316 SST for saline atmosphere (IPW/TYPEX)
(8)
Copper Free Aluminum (IPW/TYPEX)
(8)
CODE
Identification Plate
I1
I4
I5
I6
I7
FM: XP, IS, NI, DI
EXAM (DMT): Ex-ia; NEMKO: Ex-d
CEPEL: Ex-d, Ex-ia
Without Certification
EXAM (DMT) Grupo I, M1 Ex-ia
IC
IF
IJ
IO
IR
IECEX MINING
IECEX
NEMKO: EEX-D
CEPEL (Combustible Dust)
TIBR CJSC - GOST RUSSIA: EX-D, EX-IA
CODE
Painting
P0
P1
P2
P3
Munsell N 6,5 Gray
Blue Safety N4845 (standard 1374 Petrobras)
Blue Safety N4845 (standard 1735 Petrobras)
Polyester Black
P8
P9
Without Painting
Blue Safety Base Epoxy
– Electrostatic Painting
CODE Manufacturing Standard
S0
S5
SMAR
BASF
CODE Display Unit
Y0
Y1
Y2
Y3
Percentage
Display 1: Current (mA)
Display 1: Pressure (Eng. Unit)
Display 1: Temperature (ºC)
Y4
Y5
Y6
YU
Display 2: Current (mA)
Display 2: Pressure (Eng. Unit)
Display 2: Temperature (ºC)
Y
User’s specification
(7)
CODE Tag Plate
J0
J1
With TAG
Without TAG
J2
User’s specification
CODE Burn Out
BD
Down scale
BU
Up scale
CODE Flange Face
Q0
Q1
Raised Face RF (ASME DIN)
Flat Face FF (ASME DIN)
Q2
Ring Joint Face (RTJ)
CODE
Lower Housing Connection
U0
U1
U3
U4
U5
With 1 Flush Connect
ion 1/4” NPT (if supplied with lower housing)
With 2 Flush connections 1/4NPT per 180º
With 2 Flush connections 1/2NPT per 180º (with cover)
Without flush connections
With 1 Flush Connection 1/2
” NPT (with cover)
CODE Special options
ZZ
See notes
LD290L
C1
GO
H0
I1
P0
S0
Y0**
J0
BD
Q0
U0
ZZ
Typical Model Number
**Can choose 1 option for each Display (1 and 2)
NOTES
(1)
Silicone Oils not recommendations for Oxygen (O
2
) or Chlorine service.
(2)
Not applicable for vacuum service.
(3)
Thread PG13.5 certified Exd in CEPEL.
Threads ½ BSP ¾ BSP and Z (user option) is not certified Exd.
(4)
Attention, check corrosion rate for the process, tantalum, and titanium plate 0.1 mm, AISI 316L extension 3 to 6mm.
(5)
Fluorolube fill fluid is not available for Monel diaphragm.
(6)
Inert Fluid: Safe for oxygen service.
(7)
Limited values to 4 1/2 digits; limited unit to 5 characters.
(8)
IPW/TYPEX was tested for 200 hours.
(9)
IPX8 tested for 10 meters of water column for 24 hours.
(10)
process connection NPS1 and DN25 only available without extension
(11)
Meets NACE material recommendation per MR-01-75.
(12)
Inert fluid: safe for oxygen service.
Summary of Contents for LD290
Page 1: ......
Page 2: ......
Page 6: ...LD290 Operation and Maintenance Instruction Manual VI...
Page 9: ...Installation 1 3 Figure 1 1 b Dimensional Drawing and Mounting Position for LD290 Sanitary...
Page 11: ...Installation 1 5 Figure 1 1 d Dimensional Drawing and Mounting Position for LD290 Level...
Page 18: ...LD290 Operation and Maintenance Instruction Manual 1 12...
Page 32: ...LD290 Operation and Maintenance Instruction Manual 3 10...
Page 42: ...LD290 Operation and Maintenance Instruction Manual 4 10...
Page 61: ...Appendix A A 7 CEPEL Centro de Pesquisa de Energia El trica...
Page 62: ...LD290 Certifications Information A 8...
Page 63: ...Appendix A A 9 FM Approvals...
Page 64: ...LD290 Certifications Information A 10...
Page 66: ...LD290 Appendix B B 2...