No.
Name
Description
162.08
PvEgyMtr
PV production meter reading in kWh
✓
✖
162.09
GdFeedEgyTdy
Today's grid feed-in in kWh
✓
✖
163# State
No.
Name
Description
Value
Explanation
163.01
BatMntStt
Battery maintenance charge
status: If full charge or equal-
ization charge with PV energy
has not ended after 24 hours,
163.01 BatMntStt
automati-
cally switches to
On
.
On
Charge with solar
power
: Full charge or
equalization charge ac-
tive; energy is drawn
from the utility grid
✓
✖
Wait
Charge with solar
power:
If sufficient PV
energy is available, full
charge or equalization
charge active
Off
Inactive:
No full
charge or equalization
charge active
163.02
SlfCsmpSOCArea Status of the battery utilization
range
In systems for increased self-
consumption and in battery-
backup systems, this parameter
shows in which range the state
of charge of the battery is cur-
rently in (export mode).
SlfCsmpSOC
Range for increased
self-consumption
✓
✖
PVResSOC
Range for maintenance
of the battery state of
charge
BUResSOC
Range for the battery
backup system function
BatResSOC
Range for protection
against deep discharge
ProtResSOC
Range for protection in
the event of deep dis-
charge
163.03
SlfCsmpSOCLim
Lower discharge limit for self-
consumption range as %:
With this updated display
value, the Sunny Island inverter
informs of the state of charge
up to which the battery for in-
creased self-consumption is dis-
charged (expert mode).
5% to 90%
–
✓
✖