Decommissioning
SMA America, LLC
100
SB20_25_30HFUS-eng-IUS113711
Installation Guide
12.3 Disassemble the Sunny Boy for Transport
In the event of a fault it can be that your Sunny Boy must be replaced. In this case you receive a
replacement device with a transport lid.
1. Disassembling the Sunny Boy as described in section 12.1 ”Disassembling the Sunny Boy”
2. Remove the SMA Plug-in Grounding. Turn it in counterclockwise direction and then pull it down.
☑ The SMA Plug-in Grounding is loosened from its bracket.
3. Disassemble the Quick Module as described in section 5.5 ”Disassembling the Quick Module”
☑ The Sunny Boy is disassembled for transport. Pack the Sunny Boy for transport as described in
section 12.4 ”Packaging the Sunny Boy” (page 100).
12.4 Packaging the Sunny Boy
If possible, always package the Sunny Boy in the original packaging. If it is no longer available, you
can also use an equivalent box. The box must be completely closeable, have a handle system and
made to support both the weight and size of the Sunny Boy.
12.5 Storing the Sunny Boy
Store the Sunny Boy in a dry place where ambient temperatures are always between
‒13 °F (‒25 °C) and +140 °F (+60 °C).
12.6 Disposing of the Sunny Boy
Dispose of the Sunny Boy at the end of its service life in accordance with the disposal regulations for
electronic waste which apply at the installation location at that time. Alternatively, send it back to
SMA with shipping paid by sender, and labeled ”FOR DISPOSAL” (contact see section 15 ”Contact”
(page 109)).
12.7 Supplementary Information
12.7.1 Connect wires to DC terminal block
Proceed as follows, in order to fix the wires into the terminals of the terminal block:
Strip the end of the wire to a length of
1
⁄
2
in.
(12 mm).