SMA America, LLC
Configuring the Sunny Boy
Installation Guide
SB20_25_30HFUS-eng-IUS113711
33
5.2 Configuring the Quick Module
The Sunny Boy can be configured in two ways for several countries and grids.
• By using the two rotary switches (A) and (B) of the Quick Module.
• By changing the parameters ”CntrySet” or ”Sett.country stand.” using an external
communication device with
Bluetooth
interface.
If you don’t want to use
Bluetooth
communication, deactivate
Bluetooth
completely by turning the
NetID of the inverter to "0" (see section "Configuration for Bluetooth communication" on page 34).
5.2.1 Configuration before installation
If you have not yet installed the Quick Module into the Sunny Boy, proceed as follows for the
configuration:
1. Open the Quick Module by fliping up the lower flap of the Quick Module and opening the lid
of the Quick Module until it locks in place.
2. Set the arrows on both left rotary switches
(A and B) to the desired positions using a
1
⁄
8
in. (2.5 mm) screw driver.
See table in section 5.1.1 ”Country setting via
rotary switch” (page 31).
☑ The language and installation country are set.
You can configure the Quick Module before connecting it to the Sunny Boy.
Jumper for English language.
The possibility to swap the language to English
exists additionally via a jumper (e.g. during
maintenance work).
• Plug the jumper onto both left pins as
shown on the right.