57
5251
5
2022
-
SPS-B
STARTUP procedure
From HOME menu:
1. Touch STARTUP and MAINTENANCE
2. Touch STARTUP (1234 - enter)
3. Touch STARTUP BLEED
Check Pressure On Accumulator Gauge
(NB: Ac Pump Standby Pressure
(75 BAR VF650, 90 BAR VF800/VF1350, 100 BAR VF1050, 110 BAR VF1650/VF1950 Vector Fins.)
Start-Up
MC_0244
IMPORTANT
Before running or making setting adjustments in STARTUP, SEA TRIAL and Parameter SETTINGS ensure that:
- Complete Hydraulic and Electrical system is up and running
- Stabilizer system (also At Anchor) is in OFF status on the panel.
- AC pump is AUTO/ON or PTO is ON.
WARNING
During STARTUP procedure fi ns/actuators will move, ensure that health and safety
measures will be taken
1. Touch START (Bleed actuators)
Bleeding procedure will take some time.
The bleeding procedure is used to circulate oil through the hoses to flush any gas (air) out of the hydraulic system. Hose/piping routing might require
the bleeding to be performed several times.
Proceed to the DETECT ENDSTOP menu.
Return to STARTUP screen
2. Touch DETECT ENDSTOP
3. Ensure correct Actuator and Fin type selected.
Touch NEXT
4. Touch START
5. The end stop detection is required as it defi nes the actuator stroke. When the procedure is complete, press the RETURN arrow to go back to the
STARTUP menu:
Proceed to the ZERO INCLINATION menu.
Start-Up
MC_0244
WARNING
Fins/actuators will move
WARNING
Fins/actuators will move
MG_0276
1
2
3
4
5