Table 12.33. Register 0x0041 OOF0 Divider Select
Reg Address
Bit Field
Type
Name
Description
0x0041
4:0
R/W
OOF0_DIV_SEL
Values calculated by CBPro.
Table 12.34. Register 0x0042 OOF1 Divider Select
Reg Address
Bit Field
Type
Name
Description
0x0042
4:0
R/W
OOF1_DIV_SEL
Values calculated by CBPro.
Table 12.35. Register 0x0043 OOF2 Divider Select
Reg Address
Bit Field
Type
Name
Description
0x0043
4:0
R/W
OOF2_DIV_SEL
Values calculated by CBPro.
Table 12.36. Register 0x0044 OOF3 Divider Select
Reg Address
Bit Field
Type
Name
Description
0x0044
4:0
R/W
OOF3_DIV_SEL
Values calculated by CBPro.
Table 12.37. Register 0x0045 OOFXO Divider Select
Reg Address
Bit Field
Type
Name
Description
0x0045
4:0
R/W
OOFXO_DIV_SEL
Values calculated by CBPro.
Table 12.38. Register 0x0046-0x0049 Precision OOF Set Thresholds
Reg Address
Bit Field
Type
Name
Description
0x0046
7:0
R/W
OOF0_SET_THR
Precision OOF Set Threshold. The
range is up to ±500 ppm in 1/16
ppm steps.
Set Threshold (ppm) =
OOFx_SET_THR x 1/16 ppm
OOF will be indicated if this is set
to 0.
0x0047
7:0
R/W
OOF1_SET_THR
0x0048
7:0
R/W
OOF2_SET_THR
0x0049
7:0
R/W
OOF3_SET_THR
Table 12.39. Register 0x004A-0x004D Precision OOF Clear Thresholds
Reg Address
Bit Field
Type
Name
Description
0x004A
7:0
R/W
OOF0_CLR_THR
Precision OOF Clear Threshold.
The range is up to ±500 ppm in
1/16 ppm steps.
Clear Threshold (ppm) =
OOFx_CLR_THR x ±1/16 ppm
Note that OOF will be indicated if
this is set to 0.
0x004B
7:0
R/W
OOF1_CLR_THR
0x004C
7:0
R/W
OOF2_CLR_THR
0x004D
7:0
R/W
OOF3_CLR_THR
Si5386 Rev. E Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
84
Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 9, 2021
84