Table 12.141. Register 0x059B Holdover Exit
Reg Address
Bit Field
Type
Name
Description
0x059B
1
R/W
INIT_LP_CLOSE_HO
PLL acquisition method for Free run
to Lock transition.
0: Normal loop closure
1: Holdover exit ramp (default)
0x059B
4
R/W
HOLD_PRESERVE_HIST
Preserve Holdover history when the
input clock is lost or switched.
0: Clear Holdover history when the
input clock is lost or switched.
1: Preserve Holdover history when
the input clock is lost or switched.
(default)
0x059B
5
R/W
HOLD_FRZ_WITH_INTONLY
Holdover Freeze control when the in-
put clock is lost or switched.
0: Use filter output on Freeze.
1: Use Integrator-only on Freeze.
(default)
0x059B
6
R/W
HOLDEXIT_BW_SEL0
Holdover Exit Bandwidth select.
Only valid when both HOL-
DEXIT_BW_SEL0 = 0 and
HOLD_RAMP_BYP = 1.
0: Use Fastlock Bandwidth on Hold-
over exit
1: Use Holdover Exit Bandwidth on
Holdover Exit (default)
0x059B
7
R/W
HOLDEXIT_STD_BO
1: Default setting, do not modify
0: Reserved
Table 12.142. Register 0x059C DSPLL Holdover Exit Control
Reg Address
Bit Field
Type
Name
Description
0x059C
6
R/W
HOLDEXIT_ST_BO
Value set by CBPro.
0x059C
7
R/W
HOLD_RAMPBP_NO
HIST
Value set by CBPro.
Si5386 Rev. E Reference Manual • Register Map