4.9 Dynamic Output Skew Control
The input to output skew can be adjusted dynamically. This involves changing the output phase of the N divider; so the phase for all
outputs that are driven by a given Nx will change together.The dynamic phase adjust can be initiated at any time under register control.
A reset or power cycle will cause all previous effects of the phase step and count to be removed. The output skew is changed by setting
the Phase Inc or Phase Dec bit.
Table 4.18. Dynamic Output Skew Control Registers
Register Name
Hex Address [Bit Field]
Function
N0_PHASE_STEP[7:0]
0x0A38
Nx_PHASE_STEP*67.8 ps is the step size in seconds.
Total change in delay is Nx_PHASE_COUNT times
Nx_PHASE_STEP*67.8 ps. The direction of the delay ad-
justment is defined asserting either Nx_PHASE_INC or
Nx_PHASE_DEC.
N0_COUNT_COUNT[15:0]
[ [0x0A3A[7:0] 0x0A39[7:0]
N0_PHASE_DEC
0x0A3B[1]
N0_PHASE_INC
0x0A3B[0]
N1_PHASE_STEP[7:0]
0x0A3C
N1_COUNT_COUNT[15:0]
[ [0x0A3E[7:0] 0x0A3D[7:0] ]
N1_PHASE_DEC
0x0A3F[1]
N1_PHASE_INC
0x0A3F[0]
N2_PHASE_STEP[7:0]
0x0A40
N2_COUNT_COUNT[15:0]
0x0A42,0x0A41
N2_PHASE_DEC
0x0A43[1]
N2_PHASE_INC
0x0A43[0]
N3_PHASE_STEP[7:0]
0x0A44
N3_COUNT_COUNT[15:0]
0x0A46,0x0A45
N3_PHASE_DEC
0x0A47[1]
N3_PHASE_INC
0x0A47[0]
N4_PHASE_STEP[7:0]
0x0A48
N4_COUNT_COUNT[15:0]
0x0A4A,0x0A49
N4_PHASE_DEC
0x0A4B[1]
N4_PHASE_INC
0x0A4B[0]
Si5386 Rev. E Reference Manual • Output Clocks