Table 12.191. 0x0A5B N3 IODELAY Static Increment and Decrement
Reg Address
Bit Field
Type
Name
Description
0x0A5B
0
R/W
N3_IODE-
LAY_INC_EN
Upon power up or hard reset, the
IODELAY will increment or decre-
ment depending upon which bit is
set.
0x0A5B
1
R/W
N3_IODE-
LAY_DEC_EN
The following tables for N4 static IODELAY control work the same as N0 static IODELAY control.
Table 12.192. 0x0A5C N4 Static IODELAY STEP
Reg Address
Bit Field
Type
Name
Description
0x0A5C
7:0
R/W
N4_IODE-
LAY_STEP[7:0]
Static Delay control Step Size, see
section
for additional information.
Table 12.193. 0x0A5D-0x0A5E N4 Static IODELAY COUNT
Reg Address
Bit Field
Type
Name
Description
0x0A5D
7:0
R/W
N4_IODelay_COUNT Lower Byte of IO DELAY COUNT
0x0A5E
15:8
R/W
N4_IODelay_COUNT Upper Byte of IO DELAY COUNT
Table 12.194. 0x0A5F N4 IODELAY Static Increment and Decrement
Reg Address
Bit Field
Type
Name
Description
0x0A5F
0
R/W
N4_IODE-
LAY_INC_EN
Upon power up or hard reset, the
IODELAY will increment or decre-
ment depending upon which bit is
set.
0x0A5F
1
R/W
N4_IODE-
LAY_DEC_EN
Table 12.195. Register 0x0B24 Reserved Control
Reg Address
Bit Field
Type
Name
Description
0x0B24
7:0
R/W
RESERVED
Reserved
Table 12.196. Register 0x0B25 Reserved Control
Reg Address
Bit Field
Type
Name
Description
0x0B25
7:0
R/W
RESERVED
Reserved
This register is used when making certain changes to the device. See
2.1.1 Updating Registers During Device Operation
for more
information.
Si5386 Rev. E Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
126
Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 9, 2021
126