background image

1.  

2.  

3.  

4.  

5.  

6.  

7.  

RBM11G

Safety Warnings

Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing 

accidents.

Ultimate disposal of this product should be handled according to all national laws and regulations.

All installation methods for mounting an access point on any wall surface is subject to the acceptance of local jurisdiction.

The Installation of the equipment must comply with local and national electrical codes.

This product is intended to be mounted outdoors on a pole but can also be installed indoors. Please read the mounting instructions carefully before 

beginning installation. Failure to use the correct hardware and configuration or to follow the correct procedures could result in a hazardous situation to 

people and damage to the system.

Use only the power supply and accessories approved by the manufacturer, and which can be found in the original packaging of this product.

Read the installation instructions before connecting the system to the power source.

We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your 

own risk!

In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.

It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling 

requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik radio devices must be professionally installed.

First use

Insert the miniPCIe card (not included), please see paragraph 

.

MiniPCIe slot

(Optional) Install the device in a case.

Connect antenna cables to the miniPCIe card and an Ethernet cable to the gigabit Ethernet port.

Plug-in power cable to turn on the device.

We recommend connecting to the device using Winbox with a default IP address of 192.168.88.1 with the username admin and no password.

Mounting

M11G router for professional use. Each of the devices comes in ESD protective packaging. When handling electrical equipment please observe the 

following safety precautions:

Use a wrist grounding strap when unpacking and working with electrical components to avoid electrical discharge (ESD) damage.

After unpacking please place the router on the anti-static mat.

When mounting unit make sure there are no objects that can damage or touch the PCB plate.

Note that ETH and DC jack is extending over the perimeter of the PCB plate.

The device can be mounted in your desired location using the factory provided four holes in a PCB plate, located on each side of the device.

MiniPCIe slot

Installing a miniPCIe module should be done by a qualified person, please follow safety precautions when handling electrical equipment:

Place the device on the anti-static mat.

Locate the miniPCIe slot and remove two factory attached screws.

Attach provided a thick thermal pad to the card, and install the card into miniPCIe slot so that the thermal pad is between PCB and card.

The secure card in place using previously removed two screws.

Attach the grey uFL connector to the MAIN antenna connector of the modem, attach the black cable to the secondary (or AUX) connector.

Attach a thinner thermal pad to the top of the card.

Mount unit in your desired location.

After you mounted the device, slide in the SIM card from your mobile operator into the SIM slot, with the chip facing down. The slot accepts miniSIM (2FF).

Powering

Summary of Contents for RBM11G

Page 1: ...e card not included please see paragraph MiniPCIe slot Optional Install the device in a case Connect antenna cables to the miniPCIe card and an Ethernet cable to the gigabit Ethernet port Plug in power cable to turn on the device We recommend connecting to the device using Winbox with a default IP address of 192 168 88 1 with the username admin and no password Mounting M11G router for professional...

Page 2: ...it Ethernet port With Auto MDI X so you can use either straight or cross over cables for connecting to other network devices The Ethernet port accepts 10 30V DC powering from a passive PoE injector miniPCIe slot for either an 802 11 wireless card or a 3G LTE modem SIM slot is available for miniPCIe 3G LTE modems and has no functionality when a modem is not installed Buttons and jumpers RouterBOOT ...

Page 3: ...uipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure...

Page 4: ...La operacion de este equipo esta sujeta a las siguientes dos condiciones Es posible que este equipo o dispositivo no cause interferencia perjudicial y Este equipo debe aceptar cualquier interferencia incluyendo la que pueda causar su operacion no deseada Fabricante Mikrotikls SIA Brivibas gatve 214i Riga LV 1039 Latvia País De Origen Letonia Lituania China Republica Popular Estados Unidos De Ameri...

Reviews: