![Skov DOL 535 Technical Manual Download Page 44](http://html1.mh-extra.com/html/skov/dol-535/dol-535_technical-manual_1289282044.webp)
DOL 535 • DOL 539
44
Technical Manual
Activate and deactivate the water meter relay.
Check that the solenoid valve changes.
Read whether the values change to check for connection to the
water meters.
Water level
Read whether the values are correct in relation to the current
water level.
5.2.1.12 Testing door opening
Testing the door opening can be used for pop-holes, winter garden, nests and scratching area.
The test is to show if the door can open, close and stop.
Select the menu
Technical | Manual/auto.
Then select
Climate | FreeRange | Pop holes
or
Winter garden | Pop holes control
or
Winter garden control
or
Production | Nest
or
Scratching area
and activate
Manual mode
.
Then select in turn
Open
,
Close
and
Stop
.
Check that the door changes position as expected.
5.2.1.13 Testing egg counter
Select the menu
Technical | Manual/auto.
Then select
Production | Egg counters
Check that the egg counter is closed correctly in relation to the
intended location.
Look in the menu
Technical | Installation | Manual in-
stallation | Production | Eggs | Configure eggs per pulse
how
many eggs are required to trigger a pulse and run this number
of eggs through so that the result changes.
Egg counter inputs
Check that the input is connected correctly in relation to the in-
tended position(s).
5.2.1.14 Testing the poultry scale
Select the menu
Technical | Manual/auto.
Then select
Production | Bird scale