Heating
• Check that the unit which you activate in the house controller is the unit intended for the house.
Relay heating
• Check the direction of rotation of the fan in the heating units.
• Check that the heating system can start and stop.
0-10 V heating
• Check that the shunt valve can open and close and find a position of rest, e.g. 50 %.
• Check that the minimum and maximum voltage is suited for the relevant shunt.
• In order to test heating systems, set 0 % first and then 100 % to check whether or not the heater can stop
the heat supply and can supply heat constantly.
Stir fan
• Check that the fan can start and stop.
Tunnel cooling/ Soaking
• Check that the pump can start and stop.
• Check that the pump supplies water as intended.
• Check the safety switch for lack of water.
• Check the system for leaks.
5.2.1.6 Emergency inlet
Select the menu
Technical | Manual/auto.
Then select
Climate | Emergency Inlet
and activate
Manual mode
.
Activate the emergency air inlet.
Check that the emergency air inlet opens completely.
5.2.2 Testing production functions
5.2.2.1 Testing light
Select the menu
Technical | Manual/auto.
Then select
Production
, select the required type of light and activate
Manual mode
.