DOL 434 LPV
36
Technical Manual
°C
Day
Day
0
35
Limit
21 °C
18 °C
Figure 5: Curve for outside temperature limit
The Outside temperature limit can be regulated via a curve over two day numbers so that ventilation can be lim-
ited when there are small animals in the house. The limit is factory set to 18 °C for both day numbers.
6.1.1.5 Setting of Heating
Pre runtime
Time from the heating relay is picked up until heating is physically supplied (flush
time)
Adjust heaters 0-10V
Heater min. voltage
At heating requirement, the analogue voltage will never be lower than
Minimum
voltage.
Heater max. voltage
The heating shunt works at maximum output at this voltage
6.1.1.6 Setting of day and night adjustment
Adaption period
When the function is activated, the temperature adjustment will be reached after this
period.
Return period
When the function is ended, the temperature adjustment will be stopped after this pe-
riod.