DOL 434 LPV
12
Technical Manual
3.6.4 Shared equipment
Controllers in the same network (see
) can share equipment such as outside tempera-
ture sensor and outside humidity sensor.
The controller where the equipment is physically connected is called the ‘Master’. The other controllers are
called ‘Clients’.
A climate or production controller may be the’ Master’ of connected equipment while it is also the ‘Client’ of
equipment connected to another controller.
If the connection between the controllers is lost, an alarm appears on both the ‘Master’ and the ‘Client’
controller.
Example of shared outside temperature sensor - setup in ‘Client’ controller
Select the menu
Techical | Installation | Manual in-
stallation | Climate | Sensors | Temperature sensor
Activate
Use shared outside temperature sensor
.
Select the controller where the outside temperature sensor is
connected.
The name of the controller providing the outside temperature is
shown in the display.
3.7 Climate
3.7.1 Air inlets
The house controller includes different types of air intake:
Roof inlet
Air inlet in the roof which regulates via a flap, a fan and a recirculation fan.
Side inlet
E.g. wall inlets regulated by a winch motor.
A combination of the two types of air inlets allows the possibility to accommodate an increasing need for ventila-
tion by automatic adjustment of the ventilation mode.