40
Replacement Procedures
Service Manual
SKOPE BackBar X
6
Replacement Procedures
Isolating Electrics
To isolate the chiller from the power supply, either unplug the cabinet from
the wall, or use the isolation switch to turn off electrics to the cabinet and
refrigeration unit. The isolation switch is located behind the unit cover, inside
the refrigeration unit compartment.
To isolate the electrics (integral cabinet pictured)
1. Unscrew the two screws
at the top of the unit cover,
and lift the unit cover off
the cabinet to remove.
Note:
The electronic
controller is attached to
the unit cover. Take care
of cables when removing
the unit cover, and if
necessary, detach the
electronic controller.
2. Switch off (O) the power at
the isolation switch, and
unplug the IEC plug.
Note:
On remote
cabinets, the isolation
switch and IEC plug is
located towards the
bottom of the
compartment.
3. Once the maintenance work has been completed, reconnect the plug and
turn the isolation switch back on (I) before refitting the unit cover.
Isolation switch
Electronic controller
(detached from unit
cover)
Unit cover
(removed)