39
SKOPE BackBar X
Installation
Service Manual
Remote Cabinet Installation
Only applicable for cabinets with remote refrigeration systems.
SKOPE horizontal remote cabinets are supplied with a seperate instruction
sheet:
Guidelines for SKOPE remote Refrigeration
(PRN2362)
.
Refer to this
sheet for SKOPE remote refrigeration installation guidelines and
specifications.
Power Supply
The power cord and isolation switch is located in the evaporator unit
compartment. The power supply should be connected or hardwired by a
qualified person during installation of the remote refrigeration system. If the
chiller does not power up when the cabinet is connected to the power supply,
check that the isolation switch in the evaporator unit compartment is
switched on (see page 40).
Electronic
Controller
When the cabinet is connected to the power supply, the electronic controller
will display the current cabinet temperature. On the controller display, the
symbol will indicate the compressor output signal has been initiated and the
symbol will indicate the evaporator fan is on.
Pipe Locations
Refer to the images below for component locations and unit access points.
Unit pipework cover
Refrigeration unit compartment
(unit pipework cover removed)
Drain tube
Suction line
Liquid line
Rear of cabinet