16
Electronic Controller
Service Manual
SKOPE BackBar X
Programming the Electronic Controller
The electronic controller parameter configuration program is set by SKOPE
at the factory. A label on the controller box indicates the parameter
configuration program number (e.g. the BackBar X Series use program 100
(integral) and 103 (remote).
The electronic controller parameters can be modified using the keypad.
Frequent parameters can be access and changed without entering a
password (e.g. temperature setpoint). Locked parameters are protected by
a password to prevent accidental or unauthorised modifications.
Temperature
Setpoint
The chiller temperature setpoint is factory set at 1.0°C for storage of
perishable products (all shelves maintain temperatures below 5°C). The
cabinet setpoint can be adjusted between 0°C and 3.5°C if required (see
over page).
SKOPE do not recommend that the setpoint be changed unless it is
absolutely necessary, and then only by small increments at a time.
To view and adjust the temperature setpoint
Parameters
Follow the steps below to access the locked parameters.
To access the locked parameters
1. Press and hold the
Set (mute)
button for 3 seconds
until
PS
is shown on the display, indicating entry into
the controller settings menu.
2. Press the
up
or
down
button to scroll the menu until
St
is shown on the display.
3. Press the
Set (mute)
button. The current setpoint value is shown on the
display.
4. Press the
up
or
down
button to increase or decease the setpoint value to the
required temperature.
5. Press the
Set (mute)
button to temporarily save the setpoint value.
6. Press and hold the
Set (mute)
button for 3 seconds to permanently save the
setpoint value and exit the controller settings menu.
1. Press and hold the
Set (mute)
button for 3 seconds until the display shows
‘
PS
’.
2. Press the
Set (mute)
button to access the password parameter, ‘
0
’ is
displayed.
3. Use the
ES (up)
and
Light (down)
buttons to display the password ‘
22
’
(default password).
4. Press the
Set (mute)
button to confirm the password. The display shows
‘
PS
’.
5. Use the
ES (up)
and
Light (down)
buttons to scroll the parameter codes and
locate the required parameter.
Parameter categories can be identified by the initial symbol or letter of the
code, and the icon displayed on the electronic controller faceplate: