SKOPE BackBar X
Installation
Service Manual
5
Installation
Locating the Cabinet
Climate Class
The chiller is designed to operate within a climate class 5 environment (40°C
@ 40% RH). We recommend that you put the chiller in the coolest place
possible because it will use less power and last longer.
Location
When positioning the cabinet, avoid direct sunlight and warm draughts etc.
The cabinet must NOT be situated where it is affected by warm or hot air
from adjacent equipment, as this will compromise the airflow and
performance of the cabinet.
The cabinet must be positioned on a level surface for the doors to shut and
seal correctly, and to prevent the condensate tray from overflowing.
Adequate allowance should be made for door opening.
Always ensure that the top of the cabinet is shielded from impact and
moisture, with either a SKOPE provided bench top, or with a custom or
existing bench top.
When installing the cabinet
Avoid direct sunlight and warm draughts etc.
Allow adequate space for the doors to open fully.
Ensure the cabinet is positioned on a level surface so the doors shut
and seal correctly and to prevent the condensate tray from overflowing.
Ventilation
The chiller pulls air in and blows air out of from the front panel. It is essential
that adequate ventilation be provided around the front of the refrigeration
unit. Normal operating conditions should not exceed the rated climate class
(see climate class above).
It is critical that the hot refrigeration exhaust air is not restricted and that it
can easily flow out and away from the front of the cabinet. Never store
cardboard cartons or other items in front of the refrigeration unit. The
ventilation slots on the unit front cover must be kept clear at all times.