9
SKOPE TME ActiveCore
Electronic Controller
Service Manual
Defrost Cycle
The defrost cycle will begin after 2 hours (parameter dl) of cumulative
compressor run time (not real time) or during No-Downward Tendency
Protection (see over page). During the defrost cycle the compressor stops
and the evaporator fan runs continuously. The defrost cycle will terminate
when the evaporator probe reaches 4.5°C (parameter dt), or after the
defrost cycle has been running for 90 minutes (parameter dP).
Lighting
Depending on the model, the cabinet may be fitted with an LED lit sign, LED
interior sidelights and/or LED module shelf and side lights.
The electronic controller will automatically switch the lights on when the
chiller enters Normal mode, and off when the chiller enters Energy Saving
mode. Press the Light button on the electronic controller faceplate to
manually switch the lights on and off.