75
SKOPE TME ActiveCore
Replacement Procedures
Service Manual
Electronic Controller
Electronic
Controller
Location
The electronic controller is located within the electronic controller box
assembly.
To access the controller
Door Switch
The chiller is fitted with a door switch above each door, which tells the
electronic controller when a door is opened. A small magnet in the door
frame activates the switch. A cable connects the switch to the electronic
controller via an inline connector on top of the cabinet.
To remove the door switch
NTC Probe
Resistance
To test a probe for correct operation, check that its resistance falls within the
limits in the table below.
Probe resistance
1. Isolate the chiller from the power supply.
2. Open the electronic
controller box assembly
by undoing the two fixing
screws at the rear of the
assembly.
1. Isolate the chiller from the power supply.
2. Disconnect the door switch cable plug from the inline connector on top of
the cabinet.
3. Unscrew the two fixing screws from the door switch and remove from the
door switch bracket.
4. Fit the replacement door switch and connect via the inline connector.
Temperature
Resistance (k
Maximum
Typical
Minimum
-10°C
43.52
42.47
41.43
-5°C
34.66
33.90
33.15
0°C
27.83
27.28
26.74
5°C
22.45
22.05
21.66
10°C
18.25
17.96
17.67
20°C
12.24
12.09
11.94
25°C
10.10
10.00
9.90
30°C
8.41
8.31
8.21
40°C
5.92
5.83
5.74
50°C
4.24
4.16
4.08