49
12.8.8 BALANCE TIME (HOT GAS) DURING START-UP
The hot gas electro valve has to open during 5 seconds before the compressor starts. DO NOT
CHANGE
The value can be changed with “Up/Down”. By pressing “OK”, you can store this parameter
and go to the next one. The value will remain stored even if the machine is disconnected from
the mains.
12.8.9 START TIME
The start time marks the time when the machine starts up. Both the hot gas and water electro
valves connect. It is measured in minutes and seconds with a resolution of 1 second.
The value can be changed with “Up/Down”. By pressing “OK”, you can store this parameter
and go to the next one. The value will remain stored even if the machine is disconnected from
the mains.
fin.pump harv.t.
00:00 (mm:ss)
balancing time
00:05 (mm:ss)